Table 5-1: Led Description; Table 5-2: Troubleshooting - Advantech Automation1 iXC4 Hardware Manual

Pwm digital drives
Table of Contents

Advertisement

Hardware Manual
Chapter 5: Maintenance
IMPORTANT: For your own safety and for the safety of the equipment:
Do not remove the cover of the iXC4/XC4.
l
Do not attempt to access the internal components.
l
A fuse that needs to be replaced indicates that there is a more serious problem with
the system or setup. Contact Global Technical Support for assistance.
DANGER: If you must remove the covers and access any internal components be aware
of the risk of electric shock.
1. Disconnect the Mains power connection.
2. Wait at least ten (10) minutes after removing the power supply before doing
maintenance or an inspection. Otherwise, there is the danger of electric shock.
3. All tests must be done by an approved service technician. Voltages inside the
controller and at the input and output power connections can kill you.
Table 5-1:
LED Description
LED
PWR
EN/FLT
Table 5-2:
Troubleshooting
Symptom
No Communication
www.aerotech.com
Description
Color
The light will illuminate and remain illuminated while power
GREEN
is applied.
GREEN
The axis is Enabled.
RED
The axis is in a Fault Condition.
The axis is Enabled in a Fault Condition.
GREEN/RED 
or
(alternates)
The light is configured to blink for setup.
Possible Cause and Solution
Make sure the power LED is illuminated (this indicates that power is
present).
Make sure that all communication cables (HyperWire, for example) are fully
inserted in their ports.
iXC4/XC4
103