8.1

Clearances

APPLIANCE CLEARANCES WITH SINGLE
WALL PIPE CONNECTOR
Canada
A
14 ½" (368 mm)
B
12" (305 mm)
C
10" (254 mm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
13
WITH SINGLE WALL PIPE CONNECTOR
Canada
D
18" (457 mm)
E
20 ¾" (527 mm)
F
19 ¾" (502 mm)
8.1.1
With Heat Shield AC02762
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
A
3" (76 mm)
B
3" (76 mm)
C
3" (76 mm)
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
13
above mentioned.
Note that to reduce the clearances of an appliance using a single wall pipe connector, the use of a heat shield certified with the single wall pipe
14
connector to be used as close as 6" (153 mm) from combustible materials must be used. Only in this case, the same clearances as a certified double
wall pipe connector can be used.
Page 30
USA
14 ½" (368 mm)
12" (305 mm)
10" (254 mm)
FROM PIPE CONNECTOR
USA
18" (457 mm)
20 ¾" (527 mm)
19 ¾" (502 mm)
14
USA
3" (76 mm)
3" (76 mm)
3" (76 mm)
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
A
7 ½" (191 mm)
B
12" (305 mm)
C
8" (203 mm)
DISTANCES
FROM PIPE CONNECTOR
13
WITH DOUBLE WALL PIPE CONNECTOR
Canada
D
11" (279 mm)
E
20 ¾" (527 mm)
F
17 ¾" (451 mm)
DISTANCES13 FROM DOUBLE WALL PIPE
CONNECTOR
Canada
D
6 ½" (165 mm)
E
11 ¾" (298 mm)
F
12 ¾" (324 mm)
Installation and Operation Manual - Solution 3.3
USA
7 ½" (191 mm)
12" (305 mm)
8" (203 mm)
USA
11" (279 mm)
20 ¾" (527 mm)
17 ¾" (451 mm)
USA
6 ½" (165 mm)
11 ¾" (298 mm)
12 ¾" (324 mm)