Enerzone EB00060 Installation And Operation Manual page 32

Hide thumbs Also See for EB00060:
Table of Contents

Advertisement

8.1.3
With Heat Shield AC02762 and Lowered Ceiling
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
A
5" (127 mm)
B
3" (76 mm)
C
3 ½" (89 mm)
73" (1854 mm)
L
8.1.4
Inside an Alcove
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
A
10" (254 mm)
17" (432 mm)
B
K
48" (1219 mm)
70" (1778 mm)
L
8.1.5
Mobile Home
It is strictly forbidden to install a unit with a single wall pipe in a mobile home.
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
A
8" (203 mm)
B
15" (381 mm)
C
10" (254 mm)
To reduce the clearances of an appliance using a single wall pipe connector, the use of a heat shield certified with the single wall pipe connector
17
to be used as close as 6" (153 mm) from combustible materials must be used. Only in this case, the same clearances as a certified double wall
pipe connector can be used.
18
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
above mentioned.
Page 32
USA
5" (127 mm)
3" (76 mm)
3 ½" (89 mm)
73" (1854 mm)
USA
10" (254 mm)
17" (432 mm)
36" (914 mm)
70" (1778 mm)
USA
8" (203 mm)
15" (381 mm)
10" (254 mm)
17
DISTANCES FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
D
8 ½" (216 mm)
E
11 ¾" (298 mm)
F
13 ¼" (337 mm)
73" (1854 mm)
L
DISTANCES
FROM PIPE CONNECTOR
18
WITH DOUBLE WALL PIPE CONNECTOR
Canada
13 ½" (343 mm)
D
E
25 ¾" (654 mm)
DISTANCES
FROM PIPE CONNECTOR
17
WITH DOUBLE WALL PIPE CONNECTOR
Canada
D
11 ½" (292 mm)
E
23 ¾" (603 mm)
F
19 ¾" (502 mm)
Installation and Operation Manual - Solution 3.3
USA
8 ½" (216 mm)
11 ¾" (298 mm)
13 ¼" (337 mm)
73" (1854 mm)
USA
13 ½" (343 mm)
25 ¾" (654 mm)
USA
11 ½" (292 mm)
23 ¾" (603 mm)
19 ¾" (502 mm)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Solution 3.3

Table of Contents