8.1.2
With Airmate
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
A
6" (152mm)
B
12" (305 mm)
C
8" (203 mm)
With Lowered Ceiling
APPLIANCE CLEARANCES WITH SINGLE
WALL PIPE CONNECTOR
Canada
A
14 ½" (368 mm)
B
15" (381 mm)
C
12" (305 mm)
L
70" (1778 mm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
16
WITH SINGLE WALL PIPE CONNECTOR
Canada
D
18" (457 mm)
E
23 ¾" (603 mm)
F
21 ¾" (552 mm)
To reduce the clearances of an appliance using a single wall pipe connector, the use of a heat shield certified with the single wall pipe connector
15
to be used as close as 6" (153 mm) from combustible materials must be used. Only in this case, the same clearances as a certified double wall
pipe connector can be used.
Installation and Operation Manual - Solution 3.3
15
USA
6" (152mm)
12" (305 mm)
8" (203 mm)
USA
14 ½" (368 mm)
15" (381 mm)
12" (305 mm)
70" (1778 mm)
FROM PIPE CONNECTOR
USA
18" (457 mm)
23 ¾" (603 mm)
21 ¾" (552 mm)
DISTANCES13 FROM DOUBLE WALL PIPE
CONNECTOR
Canada
D
9 ½" (241 mm)
E
20 ¾" (527 mm)
F
17 ¾" (451 mm)
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
A
8" (203 mm)
B
14" (356 mm)
C
10" (254 mm)
L
70" (1778 mm)
DISTANCES
FROM PIPE CONNECTOR
15
WITH DOUBLE WALL PIPE CONNECTOR
Canada
11 ½" (292 mm)
D
E
22 ¾" (578 mm)
F
19 ¾" (502 mm)
USA
9 ½" (241 mm)
20 ¾" (527 mm)
17 ¾" (451 mm)
USA
8" (203 mm)
14" (356 mm)
10" (254 mm)
70" (1778 mm)
USA
11 ½" (292 mm)
22 ¾" (578 mm)
19 ¾" (502 mm)
Page 31