APPENDIx 3: FACEPLATE AND TRIMS INSTALLATION

Illustrations may vary by model, but the assembly method remains the same.
Hardware included with the faceplate :
• Bolts #10-24 x 1/2" (8x)
• Kit of molding brackets and screws (2x) • Nuts #10-24 (8X)
1.
Remove the faceplate extension (K) secured between the firebox and the convection air jacket.
2.
Place the faceplate panels with the finished side down on a flat, soft, non-abrasive surface.
Line up the holes of the upper faceplate panel (A) with the holes of the side panels (B) and (C).
Secure them together using four bolts (D) and nuts (E) provided. Insert the plate (F) in the
slots at the center of the upper faceplate panel (A).
Page 44
• Decorative molding fasteners (2x)
K
DETAIL K
Installation and Operation Manual - Solution 3.5-I