2. General Information

2.1

Performances

Values are as measured per test method, except for the recommended heating area, firebox volume,
maximum burn time and maximum heat output.
Models
Fuel Type
Combustion technology
Recommended heating area (sq. ft.
Overall Firebox Volume
EPA Loading Volume
Maximum burn time
1
Maximum heat output (dry cordwood)
Overall heat output rate (min. to max.)
Average overall efficiency
Dry cordwood
Optimum overall efficiency
Optimum heat transfer efficiency
Average particulate emissions rate
Average CO
11
Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type
1
and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum
acceptable temperature in the designated area in case of a power failure.
The overall firebox calculation is an approximation and is not intended to be used for loading. This volume includes a buffer zone to allow an easier
2
fuel insertion, prevent ash spillage and allow the air wash to work properly.
The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft
3
a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft
and 25%.
As measured per CSA B415.1-10 stack loss method.
4
Higher Heating Value of the fuel.
5
Lower Heating Value of the fuel.
6
7
Optimum overall efficiency at a specific burn rate (LHV).
8
The optimum heat transfer efficiency is for the low burn rate and represents the appliance's ability to convert the energy contained in the wood logs
into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.
This appliance is officially tested and certified by an independent agency.
9
Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and ASTM E3053-17
10
Carbon monoxide.
11
Page 8
)
.
1
2
3
2 4
3
7
8
9
Solution 3.5-I (EB00062)
Dry Cordwood
Non-catalytic
1,000 to 2,700 ft
(93 to 251 m
2
3.5 ft
(0.099 m
)
3
3
2.88 ft
(0.082 m
)
3
3
10 hours
110,000 BTU/h (32.2 kW)
17,200 BTU/h to 57,800 BTU/h
(5.0 kW to 16.9 kW)
71 % (HHV)
5
77 %
75 %
1.6 g/h (EPA / CSA B415.1-10)
73 g/h
and 20 lb/ft
3
Installation and Operation Manual - Solution 3.5-I
)
2
76 % (LHV)
6
10
. Other performances are based on
3
. The moisture content is between 19%