Emerson Quantum MP QMP45A4 User Manual page 52

Table of Contents

Advertisement

Safety
Product
Mechanical
Information
Information
Installation
21
0V common
Function
22
+24V user output
Function
Nominal output current
Maximum output current
Protection
23
0V common
Function
24
Digital I/O 1
25
Digital I/O 2
26
Digital I/O 3
Terminal 24 default function
Terminal 25 default function
Terminal 26 default function
Type
Input / output mode controlled by...
Operating as an input
Logic mode controlled by...
Absolute maximum applied voltage
range
Impedance
Input thresholds
Operating as an output
Open collector outputs selected
Nominal maximum output current
Maximum output current
Common to all modes
Voltage range
Sampling period
27
Digital input 1
28
Digital input 2
29
Digital input 3
Terminal 27 default function
Terminal 28 default function
Terminal 29 default function
Type of input
Logic mode controlled by...
Voltage range
Absolute maximum applied voltage
range
Impedance
Input thresholds
Sampling period
52
Electrical
Getting
Basic
Installation
Started
parameters
Common connection for all external
devices
Supply for external digital devices
200 mA (including all digital I/O)
240 mA (including all digital I/O)
Current limit and trip
Common connection for all external
devices
AT SPEED output
Not programmed
Not programmed
Positive or negative logic digital inputs,
positive or negative logic push-pull outputs
or open collector outputs
Pr 8.31, Pr 8.32 and Pr 8.33
Pr 8.29
+30V, -18V relative to 0V
Ω
6k
10.0V ±0.8V
Pr 8.30
200 mA (total including terminal 22)
240 mA (total including terminal 22)
0V to +24V
μ
250
s if configured with the destination as
Pr 6.35 or Pr 6.36. 4 ms for all other
destinations
Not programmed
LOCAL/REMOTE select
Not programmed
Negative or positive logic digital inputs
Pr 8.29
0V to +24V
+30V, -18V relative to 0V
Ω
6k
10.0V ±0.8V
μ
250
s if configured with the destination as
Pr 6.35 or Pr 6.36. 4 ms for all other
destinations
Running the
SMARTCARD
Optimization
Motor
Operation
30
0V common
Function
31
ENABLE
Function
Type
Absolute maximum applied voltage
range
Input threshold
Sampling period
Drive commissioning output
Function
Type of output
Full scale voltage range
Full scale range
Maximum offset
Protection
Model
Full scale range of drive commissioning output
QMP45A4(R)
QMP75A4(R)
QMP155A4(R)
QMP210A4(R)
41
Tachgenerator positive input
42
Tachgenerator negative input
Function
Maximum voltage
Feedback scaling controlled by
Sampling period
Status relay contacts are over-voltage category II.
WARNING
A fuse or other over-current protection should be installed to
the relay circuit.
WARNING
www.emersonct.com
Onboard
Advanced
Technical
Diagnostics
PLC
Parameters
Data
Common connection for all external
devices
Drive enable
Positive or negative logic digital input
+30V, -18V relative to 0V
10.0V ±0.8V
4 ms
Instantaneous armature current
feedback
Unipolar single-ended voltage
10V ±5%
2.3 X Drive Rated Current [Pr 11.32]
7 mV
~25 mA max. Short circuit protection to
ground (0V).
2.30 x Drive rated current
(PR 11.32)
2.42 x Drive rated current
(PR 11.32)
2.30 x Drive rated current
(PR 11.32)
2.41 x Drive rated current
(PR 11.32)
Speed feedback inputs for
tachgenerator feedback device
300V
Pr 3.51 (Fb02, 0.72)
4 ms
Quantum MP User Guide
UL
Information
Issue: A3

Advertisement

Table of Contents
loading

Table of Contents