13.4

Alarm indications

In any mode an alarm flashes alternately with the data displayed on the
2nd row when one of the following conditions occur. If action is not taken
to eliminate any alarm except "Autotune", and "PLC" the drive may
eventually trip. Alarms flash once every 640 ms except "PLC" which
flashes once every 10s. Alarms are not displayed when a parameter is
being edited.

Table 13-4 Alarm indications

Lower
display
Hot
Heatsink alarm is active
The temperature displayed in Pr 7.04 has exceeded the alarm level
(see Pr 7.04).
OVLd
Motor overload
2
The motor I
t accumulator (Pr 4.19) in the drive has reached 75% of
the value at which the drive will be tripped and the load on the drive is >
motor rated current (Pr 5.07 (SE07, 0.28)).
Autotune
Autotune in progress
The autotune procedure has been initialised. 'Auto' and 'tunE' will flash
alternatively on the display.
CLt
Current limit is active
Indicates that current limits are active.
PLC
Onboard PLC program is running
An Onboard PLC program is installed and running. The lower display
will flash 'PLC' once every 10s.
S.OV
Indicated suppressor over voltage
Indicates that the over voltage suppressor voltage is within 30V of the
trip level
S.rS
Suppressor resistor overload
Indicates that the external voltage suppressor resistor is in an overload
condition
ESt SPd
Estimated speed selected
The drive has lost speed feedback and automatically selected
Estimated speed mode. See Pr 3.55 (Select estimated speed on
feedback loss).
13.5

Status indications

Table 13-5 Status indications

Upper
Description
display
dEC
Decelerating
Speed is ramping to zero after a stop
inh
Inhibited
Enable input is inactive
POS
Position
Position control active during orientation stop
rdY
Ready
Enable closed, but drive not active
run
Running
Drive active and motor running
StoP
Stopped
Drive active, but holding zero speed.
triP
Tripped
Drive is tripped.
Quantum MP User Guide
Issue: A3
Electrical
Getting
Basic
Installation
Started
parameters
Description
Drive output
stage
Enabled
Disabled
Enabled
Disabled
Enabled
Enabled
Disabled
www.emersonct.com
Running
SMARTCARD
Optimization
the Motor
Operation
13.6

Displaying the trip history

The drive retains the last 10 trips that have occurred.
Table 13-6 shows parameters used to store the last 10 trip.
Table 13-6 Trips
Menu 0
Parameter
0.51
0.52
0.53
0.54
0.55
0.56
0.57
0.58
0.59
0.60
13.7

Behavior of the drive when tripped

If the drive trips the output of the drive is disabled so that the drive stops
controlling the motor. If any trip occurs (except UV) the following read
only parameters are frozen to help in diagnosing the cause of the trip

Table 13-7 Parameters frozen on trip

Menu 0
Parameter
0.36
1.01
1.02
0.37
1.03
0.38
2.01
0.39
3.01
0.40
3.02
3.03
0.41
3.04
0.43
4.01
5.01
0.45
5.02
5.03
5.04
5.05
5.58
0.82
7.01
0.83
7.02
0.84
7.03
10.77
Analog and digital I/O
The analog and digital I/O on the drive continue to work correctly if a trip
occurs, except the digital outputs will go low if one of the following trips
occur: O.Ld1, PS.24V.
Drive logic functions
The drive logic functions (i.e. PID, variable selectors, threshold
detectors, etc.) continue to operate when the drive is tripped.
Onboard PLC program
The Onboard PLC program continues to run if the drive is tripped, except
if one of Onboard PLC program trips occur.
Onboard
Advanced
Technical
PLC
Parameters
Data
Description
10.20
Trip 0 (most recent trip)
10.21
Trip 1
10.22
Trip 2
10.23
Trip 3
10.24
Trip 4
10.25
Trip 5
10.26
Trip 6
10.27
Trip 7
10.28
Trip 8
10.29
Trip 9
Description
Speed reference selected
Pre-skip filter reference
Pre-ramp reference
Post ramp reference
Final speed reference
Speed feedback
Speed error
Speed controller output
Current Magnitude
Armature firing angle
Armature voltage
Output power
Estimated speed
Line voltage
Field firing angle
Analog input 1
Analog input 2
Analog input 3
Input frequency
UL
Diagnostics
Information
Display
tr01
tr02
tr03
tr04
tr05
tr06
tr07
tr08
tr09
tr10
Display
di01
di02
di03
di04
di05
di06
di08
di10
in02
in03
in04
165