Installation
Parameter
12.01
Threshold detector 1 output
12.02
Threshold detector 2 output
12.03
Threshold detector 1 source
12.04
Threshold detector 1 level
12.05
Threshold detector 1 hysteresis
12.06
Threshold detector 1 output invert
12.07
Threshold detector 1 destination
12.08
Variable selector 1 source 1
12.09
Variable selector 1 source 2
12.10
Variable selector 1 mode
12.11
Variable selector 1 destination
12.12
Variable selector 1 output
12.13
Variable selector 1 source 1 scaling
12.14
Variable selector 1 source 2 scaling
12.15
Variable selector 1 control
12.23
Threshold detector 2 source
12.24
Threshold detector 2 level
12.25
Threshold detector 2 hysteresis
12.26
Threshold detector 2 output invert
12.27
Threshold detector 2 destination
12.28
Variable selector 2 source 1
12.29
Variable selector 2 source 2
12.30
Variable selector 2 mode
12.31
Variable selector 2 destination
12.32
Variable selector 2 output
12.33
Variable selector 2 source 1 scaling
12.34
Variable selector 2 source 2 scaling
12.35
Variable selector 2 control
12.40
Brake release
12.41
Brake controller enable
12.43
Lower current threshold
12.45
Brake apply speed
12.46
Brake apply speed delay
12.47
Post-brake release delay
12.48
Brake apply delay
Enable position controller during brake
12.49
release
12.50
Field active
12.51
External field control
RW Read / Write
RO
Read only
FI
Filtered
DE
Destination
128
Electrical
Getting
Basic
Running the
Installation
Started
parameters
Range(
OFF (0) or On (1)
OFF (0) or On (1)
Pr 0.00 to 22.99
0 to 100.00%
0 to 25.00%
OFF (0) or On (1)
Pr 0.00 to 22.99
Pr 0.00 to 22.99
Pr 0.00 to 22.99
Pr 0.00 to 22.99
0 to 100.00
Pr 0.00 to 22.99
0 to 100.00%
0 to 25.00%
OFF (0) or On (1)
Pr 0.00 to 22.99
Pr 0.00 to 22.99
Pr 0.00 to 22.99
Pr 0.00 to 22.99
0 to 100.00
OFF (0) or On (1)
0 to 200rpm
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
Uni
Unipolar
Bi
NC
Not copied
RA
SMARTCARD
Optimization
Motor
Operation
)
0 to 10
±100.00%
±4.000
±4.000
0 to 10
±100.00%
±4.000
±4.000
0 to 3
0 to 150%
0 to 25.0s
0 to 25.0s
0 to 25.0s
Bi-polar
Bit
Bit parameter
Rating dependent
PT
Protected
www.emersonct.com
Onboard
Advanced
Technical
Diagnostics
PLC
Parameters
Data
Default(
)
RO Bit
RO Bit
Pr 0.00
RW Uni
0.00
RW Uni
0.00
RW Uni
OFF (0)
RW Bit
Pr 0.00
RW Uni
Pr 0.00
RW Uni
Pr 0.00
RW Uni
0
RW Uni
Pr 0.00
RW Uni
RO Uni
1.000
RW Uni
1.000
RW Uni
0.00
RW Uni
Pr 0.00
RW Uni
0.00
RW Uni
0.00
RW Uni
OFF (0)
RW Bit
Pr 0.00
RW Uni
Pr 0.00
RW Uni
Pr 0.00
RW Uni
0
RW Uni
Pr 0.00
RW Uni
RO Uni
1.000
RW Uni
1.000
RW Uni
0.00
RW Uni
RO Uni
0
RW Txt
10%
RW Uni
5rpm
RW Uni
1.0s
RW Uni
1.0s
RW Uni
1.0s
RW Uni
OFF (0)
RW Bit
OFF (0)
RW Bit
OFF (0)
RW Bit
Txt
Text string
US
User save
PS
Quantum MP User Guide
UL
Information
Type
NC PT
NC PT
PT US
US
US
US
PT US
PT US
PT US
US
PT US
NC PT
US
US
US
PT US
US
US
US
PT US
PT US
PT US
US
PT US
NC PT
US
US
US
NC PT
US
US
US
US
US
US
US
US
US
Power down save
Issue: A3

Advertisement

Table of Contents
loading

Table of Contents