Emerson Quantum MP QMP45A4 User Manual page 98

Table of Contents

Advertisement

Safety
Product
Mechanical
Information
Information
Installation
Parameter
1.01
Speed reference selected
1.02
Pre-skip filter reference
1.03
Pre-ramp reference
1.04
Reference offset
1.05
Jog reference
1.06
Maximum reference clamp
1.07
Minimum reference clamp
Negative minimum reference
1.08
clamp enable
1.09
Reference offset select
1.10
Bipolar reference enable
1.11
Reference enabled indicator
1.12
Reverse selected indicator
1.13
Jog selected indicator
1.14
Reference selector
1.15
Preset selector
Preset reference selector
1.16
timer
1.17
Keypad control reference
1.18
Precision reference coarse
1.19
Precision reference fine
Precision reference update
1.20
disable
1.21
Preset reference 1
1.22
Preset reference 2
1.23
Preset reference 3
1.24
Preset reference 4
1.25
Preset reference 5
1.26
Preset reference 6
1.27
Preset reference 7
1.28
Preset reference 8
1.29
Skip reference 1
1.30
Skip reference band 1
1.31
Skip reference 2
1.32
Skip reference band 2
1.33
Skip reference 3
1.34
Skip reference band 3
1.35
Reference in rejection zone
1.36
Analog reference 1
1.37
Analog reference 2
1.38
Percentage trim
1.39
Velocity feed forward
1.40
Velocity feed forward select
1.41
Reference select flag 1
1.42
Reference select flag 2
1.43
Reference select flag 3
1.44
Reference select flag 4
1.45
Reference select flag 5
1.46
Reference select flag 6
1.47
Reference select flag 7
1.48
Reference timer reset flag
1.49
Reference selected indicator
Preset reference selected
1.50
indicator
Power-up keyboard control
1.51
mode reference
1.52
Reference select flags
RW Read / Write
RO
Read only
FI
Filtered
DE
Destination
98
Electrical
Getting
Basic
Running the
Installation
Started
parameters
Range(
{di01, 0.36}
±MAX_SPEED_REF rpm
±MAX_SPEED_REF rpm
{di02, 0.37}
±MAX_SPEED_REF rpm
±10,000.0 rpm
0 to 1,000.0 rpm
{SE02, 0.23}
SPEED_LIMIT_MAX rpm
{SE01, 0.22}
±SPEED_LIMIT_MAX rpm
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
{di11, 0.46}
OFF (0) or On (1)
{di12, 0.47}
OFF (0) or On (1)
{di13, 0.48}
OFF (0) or On (1)
{SE05, 0.26}
0 to 400.0s
±MAX_SPEED_REF rpm
±MAX_SPEED_REF rpm
0.0 to 0.099 rpm
OFF (0) or On (1)
±MAX_SPEED_REF rpm
±MAX_SPEED_REF rpm
±MAX_SPEED_REF rpm
±MAX_SPEED_REF rpm
±MAX_SPEED_REF rpm
±MAX_SPEED_REF rpm
±MAX_SPEED_REF rpm
±MAX_SPEED_REF rpm
0 to 10,000 rpm
0 to 250 rpm
0 to 10,000 rpm
0 to 250 rpm
0 to 10,000 rpm
0 to 250 rpm
OFF (0) or On (1)
±MAX_SPEED_REF rpm
±MAX_SPEED_REF rpm
±100.00%
±10,000.0 rpm
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
Uni
Unipolar
Bi
NC
Not copied
RA
SMARTCARD
Optimization
Motor
Operation
)
0 to 6
0 to 9
1 to 6
1 to 8
0 to 2
Bi-polar
Bit
Bit parameter
Rating dependent
PT
Protected
www.emersonct.com
Onboard
Advanced
Technical
Diagnostics
PLC
Parameters
Data
Default(
)
RO
Bi
RO
Bi
RO
Bi
0.0
RW
Bi
0.0
RW Uni
1,000.0
RW Uni
0.0
RW
Bi
OFF (0)
RW Bit
OFF (0)
RW Bit
OFF (0)
RW Bit
RO Bit
RO Bit
RO Bit
0 (A1.A2)
RW Txt
0
RW Uni
10.0
RW Uni
0.0
RO
Bi
0.0
RW
Bi
0.000
RW Uni
OFF (0)
RW Bit
0.0
RW
Bi
0.0
RW
Bi
0.0
RW
Bi
0.0
RW
Bi
0.0
RW
Bi
0.0
RW
Bi
0.0
RW
Bi
0.0
RW
Bi
0
RW Uni
5
RW Uni
0
RW Uni
5
RW Uni
0
RW Uni
5
RW Uni
RO Bit
0
RO
Bi
0
RO
Bi
0.00
RW
Bi
RO
Bi
RO Bit
OFF (0)
RW Bit
OFF (0)
RW Bit
OFF (0)
RW Bit
OFF (0)
RW Bit
OFF (0)
RW Bit
OFF (0)
RW Bit
OFF (0)
RW Bit
OFF (0)
RW Bit
RO Uni
RO Uni
0
RW Txt
OFF (0)
RW Bit
Txt
Text string
US
User save
PS
Quantum MP User Guide
UL
Information
Type
NC PT
NC PT
NC PT
US
US
US
PT US
US
US
US
NC PT
NC PT
NC PT
US
US
US
NC PT PS
US
US
NC
US
US
US
US
US
US
US
US
US
US
US
US
US
US
NC PT
NC
NC
NC
NC PT
NC PT
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC PT
US
NC
Power down save
Issue: A3

Advertisement

Table of Contents
loading

Table of Contents