Technical data

8
Performance specifications and guarantee only in connection with original spare and
replacement parts!
Current setting range
Voltage setting range
Duty cycle at 40 °C ambient temperature
40% DC
60% DC
100% DC
Load cycle
Open circuit voltage
Mains voltage (tolerances)
Frequency
Mains fuse
(safety fuse, slow-blow)
Mains connection lead
Max. connected load
Recommended generator rating
cos/efficiency
Ambient temperature*
Machine cooling/torch cooling
Workpiece lead
Insulation class/protection
classification
EMC class
Safety identification
Other standards used
Cooling capacity at 1 l/min.
Max. flow rate
Max. coolant outlet pressure
Tank capacity
Wire spool diameter
Dimensions (L x W x H)
Weight
*Ambient temperature depends on coolant! Observe the coolant temperature range for the
welding torch cooling!
099-005442-EW501
02.09.2016
Fixing the pump shaft (coolant circuit)
MIG/MAG
5 A–350 A
14.3 V–31.5 V
350 A
300 A
270 A
10 min. (60% DC
6 min. welding, 4 min. pause)
79 V
3 x 400 V (-25% to +20%)
50/60 Hz
3 x 16 A
H07RN-F4G2,5
14.3 kVA
20.8 kVA
0.99/88 %
-25 C to +40 C
Fan (AF)/water
50 mm
H/IP 23
A
/
IEC 60974-1, -5, -10
1000 W
5 l/min.
3.5 bar
5 l
Standardized wire spools up to 300 mm
625 mm x 300 mm x 810 mm
24.6 x 11.8 x 31.9 inch
49 kg
108 lb
Technical data
MMA
20.2 V–34.0 V
15.4 kVA
2
/
67