Reset To Factory Settings; Special Parameters In Detail - EWM Taurus 355 Basic TKW Operating Instructions Manual

Hide thumbs Also See for Taurus 355 Basic TKW:
Table of Contents

Advertisement

Design and function
Special parameters (advanced settings)
5.6.1.1

Reset to factory settings

All special parameters saved by the user will be overwritten by the factory settings!
Display
5.6.1.2

Special parameters in detail

Ramp time for wire inching (P1)
The wire inching starts with a speed 1.0 m/min for 2 secs. It is subsequently increased to a ramp function
to 6.0 m/min. The ramp time can be set between two ranges.
During wire inching, the speed can be changed by means of the welding parameter setting rotary dial.
Changing the speed has no effect on the ramp time.
Latched/special-latched tap start (P9)
In latched – tap start – operating mode it is possible to switch straight to the second step by tapping the
torch trigger; it is not necessary for current to be flowing.
The welding can be halted by pressing the torch trigger for a second time.
Electronic gas flow control, type (P22)
Active only in machines with integrated gas flow control (option ex works).
Adjustment may only be carried out by authorised service personnel (basic setting = 1).
54
RESET
0
l
Setting/selection
Initialisation complete
All customised welding parameters haven been overwritten by the factory settings.
+
0
l
Figure 5-30
099-005442-EW501
02.09.2016