5.7
Machine configuration menu
5.7.1
Selecting, changing and saving parameters
ENTER (Enter the menu)
•
Switch off the machine at the main switch.
•
Press and hold down the "Welding procedure" push-button and switch the machine on again
at the same time.
NAVIGATION (Navigate the menu)
•
Select parameters by turning the "Welding parameter setting" rotary knob.
•
Set or change the parameters by turning the "Welding voltage" rotary knob.
EXIT (Exit the menu)
•
Press the "Push-button, parameter selection right" push-button (switch machine off and on
again).
Enter
Display
099-005442-EW501
02.09.2016
0
l
Setting/selection
Lead resistance 1
Lead resistance for the first welding circuit 0 mΩ–60 mΩ (8 mΩ ex works).
Only qualified service personnel may change the parameters!
Time-controlled power-saving mode > see 5.7.2 chapter
• ----------- 5 min.–60 min. = time until activation of power-saving mode when inactive.
• ----------- off = switched off
Service menu
Modifications to the service menu may only be carried out by authorised maintenance
staff!
Design and function
+
Figure 5-31
Machine configuration menu
Exit
0