EWM Taurus 355 Basic TKW Operating Instructions Manual page 53

Hide thumbs Also See for Taurus 355 Basic TKW:
Table of Contents

Advertisement

Enter
Display
099-005442-EW501
02.09.2016
0
l
Setting/selection
Ramp time for wire inching
0 = -------- normal inching (10s ramp time)
1 = -------- fast inching (3s ramp time) (Ex works)
Lat. and sp. lat. tapping start
0 = -------- no latched tapping start (Ex works)
1 = -------- latched tapping start possible
Support for wire feeders with voltage-sensing.
0 = ------- Function switched off
1 = ------- Function switched on (ex works)
Remote control encoding (Frc)
0-----------Automatic remote control detection (ex works)
2-----------Remote control encoding for accessory components with a single rotary knob
only
9-----------Remote control encoding for accessory components with a single pair of
buttons or a rocker only
1, 3–8 ----No remote control encoding
10–15 ----No remote control encoding
Design and function
Special parameters (advanced settings)
+
Figure 5-29
Exit
53