Sp Tables - Sp2-Xxx (1); Sp2-Xxx (Drum) -1 - Ricoh MP C307 Field Service Manual

Hide thumbs Also See for MP C307:
Table of Contents

Advertisement

SP Tables - SP2-XXX (1)

SP2-XXX (Drum) -1

SP
Large Category
No.
2-
Charge DC Voltage: Fix
005-
001
2-
Charge DC Voltage: Fix
005-
002
2-
Charge DC Voltage: Fix
005-
003
2-
Charge DC Voltage: Fix
005-
004
2-
Environmental Correction: PCU
013-
001
2-
Environmental Correction: PCU
013-
002
2-
Lubricant Apply Operation
016-
001
2-
Lubricant Apply Operation
016-
002
2-
Lubricant Apply Operation
016-
003
2-
Lubricant Apply Operation
016-
004
2-
Lubricant Apply Operation
016-
005
Small Category
Plain: Bk
Plain: C
Plain: M
Plain: Y
Environment Div. FC:
Display
Forced Setting
Temperature Threshold:
Low
Temperature Threshold:
High
Page Setting 1: Low Speed
Page Setting 2: Low Temp.
Page Setting 3: Low Temp.
2
3.SP Mode Tables
ENG or
[Min to
CTL
Max/Init./Step]
ENG*
[ 0 to 2000 / 590 / 10-
V ]
ENG*
[ 0 to 2000 / 590 / 10-
V ]
ENG*
[ 0 to 2000 / 590 / 10-
V ]
ENG*
[ 0 to 2000 / 590 / 10-
V ]
ENG*
[ 0 to 5 / 0 / 1 ]
ENG*
[ 0 to 5 / 0 / 1 ]
ENG*
[ 0 to 50 / 15 / 1deg ]
ENG*
[ 0 to 50 / 30 / 1deg ]
ENG*
[ 0 to 999 / 10 /
1page ]
ENG*
[ 0 to 999 / 20 /
1page ]
ENG*
[ 0 to 999 / 0 / 1page ]
47