Registration - Ricoh MP C307 Field Service Manual

Hide thumbs Also See for MP C307:
Table of Contents

Advertisement

Image Adjustment
ADF Sub-scan Magnification
1.
Put the temporary test chart on the ADF. Then make a copy from one of the feed stations.
2.
Check the magnification ratio. Adjust with SP6-017-001(ADF Adjustment L-Edge Mag) if necessary.
Standard: ±5.0%
Reduction mode: ±1.0%
Enlargement mode: ±1.0%

Registration

Adjustment Standard
Image Area
[1]: Feed direction, [2]: Image area
Make sure that the registration is adjusted within the adjustment standard range.
After doing the registration adjustment, do the Erase Margin Adjustment in the next section.
Adjustment standard
Leading edge (sub-scan direction):
B = 3.25 ± 2.75 mm
Trailing edge (sub-scan direction):
D = 3.25 ± 2.75 mm
Side to side (main-scan direction):
A = C = 2.25 ± 1.75 mm
Registration Standard
Side to side
Adjusts the side-to-side registration for each paper feed station. Use SP mode (SP1-002) to adjust the
side-to-side registration for the optional paper feed unit and duplex unit.
SP No.
SP1-002-001
Side-to-Side Registration: By-pass Table
SP Name
Range
± 4.0 mm
189