Ricoh MP C307 Field Service Manual page 496

Hide thumbs Also See for MP C307:
Table of Contents

Advertisement

SC8xx: Overall System
No.
Type
No.
Type
SC876-04 D
Log Data Error 4
An error was detected in the handling of the log data at power on or during machine
operation.
Initialize the HDD (SP5-832-004).
No.
Type
SC876-05 D
Log Data Error 5
An error was detected in the handling of the log data at power on or during machine
operation.
No.
Type
SC876-99 D
Log Data Error 99
An error was detected in the handling of the log data at power on or during machine
operation.
Other causes
-
No.
Type
SC877-00 B
Data Overwrite Security card error
The "Auto Erase Memory" function of the Data Overwrite Security is set to on but it cannot
be done.
490
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Disable the log encryption setting.
Initialize LCS memory (SP5801-019).
Initialize the HDD (SP5-832-004).
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Log encryption key is disabled but the log data file is encrypted. (NVRAM data
corruption)
Log encryption key is enabled but the log data file is not encrypted. (NVRAM data
corruption)
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Only the NV-RAM has been replaced with one previously used in another machine.
Only the HDD has been replaced with one previously used in another machine.
Attach the original NV-RAM.
Attach the original HDD.
With the configuration that caused the SC, initialize the HDD (SP5-832-004).
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Data Overwrite Security option SD card is broken.