Locate the M5 thumb-screws on the top cover of the enclosure that keep it in place when the
Step 24 :
drawer is extended, and unscrew them using a T15 Torx screwdriver. This will allow the top cover
to move freely with the enclosure when the enclosure is removed.
Removing the Enclosure from the Rack
Grasp both handles at the front of the enclosure and pull with even pressure to extend the
Step 25 :
chassis out of the rack until it is stopped by the safety latches. Make sure that the top cover
comes with the chassis as it is extended out of the rack. The safety latches will prevent the
enclosure from coming out of the rack completely.
Step 26 :
Remove the chassis from the rack.
a. Be prepared to support the enclosure once it is free of the rails by having a second person or
a lift to support the enclosure
b. Grasp both handles at the front of the enclosure and pull with even pressure until the
enclosure will not extend further.
c. Locate the safety catches on the inner rails attached to the enclosure.
Warning:
The handles on the front of the chassis are not intended to be used
to support the weight of the Ultrastar Data60 . Lifting the unit by the chassis
handles or trying to support the unit on the handles can cause them to fail.
This can cause serious damage to the unit or serious bodily harm to those
handling the unit. Always team lift the chassis by gripping the underside of the
unit, and never try to lift a chassis that is filled with drives.
1. EU EcoDesign Disclosures
1.4 Ultrastar Data60 Disassembly
16