Installation Checklist; Retrofitting; Mounting Block Removal - Cornelius Post-Mix Valves UFB-1 Training Manual

Valves
Hide thumbs Also See for Post-Mix Valves UFB-1:
Table of Contents

Advertisement

3. Detach current valves:
– Remove front cover by lifting.
– Remove valve cover.
– Unplug wiring harness.
– Remove valve.

3. INSTALLATION CHECKLIST

1. Voltage and proper grounding.
2. Valve properly secured (latched) to block.
3. CO
pressure to carbonator.
2
4. Water flow rate.
5. Syrup delivery pressure.
6. Finished product temperature less than 40°F.
7. Water to syrup ratio.
8. Portion size / top-off.
9. Water, syrup, CO
leaks.
2
10. Cover secured to valve.
11. Valves flavor correctly marked.
4. R
ETROFITTING
UF-1 and UFB-1 valves will retrofit any valve with an identical mounting block screw pattern.
Note: Replacement of mounting block inlet fitting O-rings (part # 4073) is required when retrofit-
ting valves.

4.1 Mounting Block Removal

To remove valve mounting block from the front panel, take out and save 4 screws.
IMPORTANT: Before installing block replace O-rings on each outlet fitting. Lubricate
with Dow 111 or equivalent silicone lubricant. Do not use petroleum jelly.
© 1999-2005, IMI Cornelius, Inc.
UF-1 and UFB-1 Valves Training Manual
- 17 -

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uf-1