Caution!
Component damage due to material ageing
Material can age due to long storage periods, thereby affecting the material's properties (e.g.
plastics and seals may become brittle). The properties of lubricants may change due to long
storage periods.
Caution!
Component damage due to freezing liquids
Ambient temperatures that are below freezing will lead to the freezing of any water or
cleaning agent residue remaining inside the unit. This will lead to damage to internal
components.
-
Before shipment, storage or relocation of the unit, the unit is to be cleaned and the
cleaning solution is to be fully drained from the unit.

Disposal

Disposal of the units must be carried out in compliance with the applicable local and/or national and
international regulations. Units must not be disposed of with household waste.
If the unit contains fuels or lubricants in liquid, paste-like or gaseous form, such as oil, grease, cooling
agents etc., such fuels or lubricants are to be collected using appropriate measures and disposed of in
compliance with the applicable local and/or national and international regulations. Such fuels or
lubricants must always be prevented from seeping into the ground, the sewage system and any
bodies of water, and must always be prevented from entering the atmosphere.

Installation Requirements

5.1

Installation Sites

Comply with the valid national regulations for installation sites and electrical connections. Ventilation
of the installation sites must be appropriate for device output. Inadequate ventilation of the device will
result in its overheating and being destroyed. Always make certain that no intake or discharge vents
are covered.
Heat output
Air flow
5.2

Electrical Connections

A socket outlet with a grounding contact featuring a maximum protection of 16 amperes is required.
The line voltage must always be within following tolerances: 230 VAC +6%/-10% / 50 Hz
Power consumption
Cornelius Deutschland GmbH
Document no: TD1011602EN
Version A, 04.07.2019, Index 0
950 W
3
250 m
/h
850 W / 4.6 Amp
TRITON 200 HC
Manual operation undercounter cooler
Triton 200 HC
Page 10