UF-1 and UFB-1 Valves Training Manual
16. Then remove 5 screws that secure the
valve head to the valve body.
17. To remove the dispensing lever return spring pry the
end of the spring and pull up. This spring stops the
lever from vibrating.

4.2 Mounting Block Disassembly

To disassemble mounting block:
1. Turn off water and syrup supplies.
2. Remove 2 screws from top plate and pull spools
out from the bottom of the mounting plate exposing
spools and O-rings.
Note: When replacing mounting block use replace-
ment O-rings for the inlet fittings.
3. When installing a new block, make sure
it is locked in the open position..
- 12 -
Block closed (up)
Block open (down & locked)
Pry here
O-rings