USER INSTRUCTIONS

Operation of the cooler

To maintain the safe operation and reliability of the cooler during normal use, please
observe the following points:-
The cooler is designed to run continuously. During normal use it sho uld only be
switched off when cooling will not be required for a period of more than 24hours. The
cooler should be restarted at least 5hours (dependant on model) before it is to be used.
Do not spill or let liquids drop on the cooler – if liquids do spill onto the unit,
electrically isolate before wiping the spillages up.
Do not place items close to the cooler as this can reduce the air flow and reliability of
the cooler.
Do not place items on top of the cooler as this may cause damage to the agitator/pump
assemblies.
Do not move the unit once full of water.
Don not block the water tank overflow tube – any condensation generated by the
cooler must be allowed to run away.
Note: In the event of malfunction switch off and electrically isolate the cooler.
Always use a qualified Service Engineer to repair the unit – there are no user
serviceable components.

Cleaning Routine

Beer coils can be internally cleaned as part of the regular draught beer system
cleaning as follows:-
1.
Purge the beer lines with clean, cool water.
2.
Add a chlorinated alkaline solution, diluted with the correct amount of water,
to the system.
3.
Allow to stand in the pipes for the time specified by the cleaning solution
manufacturer – usually 30 minutes.
4.
Flush the system with clean, cool water to remove all traces of cleaning
solution.
5.
Refill the system with beer.
The outside of the cooler can be cleaned using a mild non- foaming aerosol cleaner
sprayed onto a dry soft cloth and wiped over the cooler. Electrically isolate the unit
whilst cleaning.

INSTALLATION

Installation to be carried out by a suitably trained person only. Compliance with local
Bylaws and Codes of Practice must be ensured.
INSTALLATION INSTRUCTIONS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Maxi series and is the answer not in the manual?

Questions and answers

Summary of Contents for Cornelius Maxi series

  • Page 1: Installation Instructions

    INSTALLATION INSTRUCTIONS USER INSTRUCTIONS Operation of the cooler To maintain the safe operation and reliability of the cooler during normal use, please observe the following points:- The cooler is designed to run continuously. During normal use it sho uld only be switched off when cooling will not be required for a period of more than 24hours.
  • Page 2 If any maintenance/servicing is required, refer to the fault finding chart, wiring diagram and exploded drawings contained in the product manual and always ensure that the following are observed:- When replacing components always use IMI Cornelius approved spare parts. Failure to do so will invalidate the coolers warranty.
  • Page 3 Always electrically isolate the cooler before removing covers or carrying out any work. After working on the cooler ensure that the unit is le ft electrically safe and that all covers and cover fixings are refitted. If replacing a condenser fan motor always fit a new fan blade. The drier must be replaced each time the refrigeration system is opened.

Table of Contents

Save PDF