All UF-1 and UFB-1 valves have a 24 volt solenoid that should be powered by an 80 kVA rated
transformer. Voltage at the coil with the solenoid energized should be 22 and 27 VAC.
5.1 UF-1 and UFB-1 Portion Control Valve
The UF-1 and UFB-1 Portion Control Valves are push and release
that dispense for a programmed duration. There are four settings:
small, medium, large, and extra-large. There is also a Cancel/Pour
rectangular button with red and green arrows. If this button is
pressed during dispensing, the flow stops. If the valve is not dis-
pensing and the button is pressed, the valve dispenses as long as the
button is held.
The portion controls are factory programmed to the following default settings:

Portion Control Valve Programming

To set the amount of beverage dispensed, follow this procedure:
1. Press the hidden program switch until the PGM light turns on. (This light shows
only when the programming mode is turned on.)
2. Put desired amount of ice in cup. Press and hold a portion button until the
desired level in the appropriate sized cup is reached. Release the button.
3. Continue with other portion buttons that need programming. Portion buttons
may be reprogrammed as many times as necessary. Only the last time values
entered for each button will be saved when exiting the programming mode.
4. Press the program switch until the PGM light turns off.
PGM lights
(not visible unless in
programming mode)
© 1999-2005, IMI Cornelius, Inc.
E
LECTRICAL
Portion Size
Pour Time
S
M
L
XL
UF-1 and UFB-1 Valves Training Manual
2 sec.
3 sec.
4 sec.
6 sec.
Program switch
(hidden)