Cornelius Post-Mix Valves UFB-1 Training Manual page 17

Valves
Hide thumbs Also See for Post-Mix Valves UFB-1:
Table of Contents

Advertisement

12. Note that the flow rate (1 ½ - 3, 3 – 4 ½ or
1 ½ - 3 juice) and date code are printed on
the retainer plate.
13. To disassemble the flow control:
Remove screws and pull retainer
forward. Remove top flow con-
trol subassemblies exposing
flow controls.
Note the difference between
high flow and ultra flow valves.
Note: Top Flow control is an
assembly and cannot be dissas-
embled.
14. Pop off solenoid cover. Remove solenoid assembly from valve body by prying with
screwdriver.
Note: Check plunger for corrosion and dirt – replace as necessary.
15. Carefully remove banjo lever springs.
© 1999-2005, IMI Cornelius, Inc.
Ultra Flow
notched
piston for
water
Pry here
Solenoid
cover
UF-1 and UFB-1 Valves Training Manual
Flow rate &
date code
Concentrate valve
sleeve has one hole
Syrup valve sleeve
has six holes
Solenoid
plunger
Spring
- 11 -