Advertisement

Triton HC range

Advertisement

Table of Contents
loading

Summary of Contents for Cornelius Triton HC Series

  • Page 1  Triton HC range...
  • Page 2 Phone: +49 (0) 21 73 / 79 3 – 0 Fax: +49 (0) 21 73 / 77 4 – 38 Email: info@cornelius.com Cornelius Deutschland GmbH Carl-Leverkus-Str. 15 40764 Langenfeld Germany Manual operation undercounter cooler...
  • Page 3: Table Of Contents

    Exploded View / Spare part list ........................27 12.1 Exploded View ............................27 12.2 Spare Part List ............................30 Declaration of conformity ..........................32 Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1011600EN Triton HC Version A, 04.04.2019, Index 0 Page 3...
  • Page 4: Safety

    By using the unit as intended you will not only protect yourself, but also prevent damage occurring to the unit and its components! The intended use of undercounter coolers from the Triton HC series (referred to as “unit” in the following) is to refrigerate and convey non-alcoholic beverages and their basic ingredients. CO2 or electric pumps are used as conveying equipment for the brands.
  • Page 5: Staff

    1.5.2 Disclaimer of liability and warranties If work is undertaken on the unit which is not described in this document, Cornelius Deutschland GmbH shall not assume any liability for any resulting hazards and damages. The same applies to described work which is partly or not fully performed in compliance with the regulations set out in this document.
  • Page 6: Safety Information To Prevent Personal Injury And Equipment Damage

    Improperly executed work at the unit will cause dangers to persons and damage to the unit.  Have all work at the unit carried out by Cornelius Deutschland GmbH or by a service partner. Warning! Risk of personal injury and equipment damage due to the use of non- approved spare...
  • Page 7: Transport And Packaging

    75). Transport and packaging Choose a suitable packaging when returning the unit itself or one of its components to Cornelius Deutschland GmbH, e.g. for repairs. In particular, make sure that the unit and any components are protected from shock/impact, moisture, dirt and electrostatic discharge (ESD). This will prevent transport damage to the unit and to the components, for which the manufacturer shall assume no liability.
  • Page 8 Before shipment, storage or relocation of the unit, the unit is to be cleaned and the cleaning solution is to be fully drained from the unit. Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1011600EN Triton HC Version A, 04.04.2019, Index 0...
  • Page 9: Transport And Packaging

    Triton HC Transport and packaging Choose a suitable packaging when returning the unit itself or one of its components to Cornelius Deutschland GmbH, e.g. for repairs. In particular, make sure that the unit and any components are protected from shock/impact, moisture, dirt and electrostatic discharge (ESD). This will prevent transport damage to the unit and to the components, for which the manufacturer shall assume no liability.
  • Page 10: Disposal

    The line voltage must always be within following tolerances: 230 VAC +6%/-10% / 50 Hz Power consumption in Watt Triton 150 HC Triton 350 HC Triton 350v HC 1200 1200 Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1011600EN Triton HC Version A, 04.04.2019, Index 0 Page 10...
  • Page 11: Installation

    Caution: A short circuit in the power supply to the valves caused a transformer switch off or a damage of the level board. Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1011600EN Triton HC Version A, 04.04.2019, Index 0...
  • Page 12: Connection Of Still Water Control

    3 minutes is valid for turning on the device and after a breakdown of the power supply. This unit contains a 3-pin ice bank probe. Take care that the probe is always correctly adjusted. Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1011600EN Triton HC Version A, 04.04.2019, Index 0...
  • Page 13: Daily Inspection

    Detach the couplings from beverage containers. Have the system emptied and cleaned. Only trained specialists are authorized to carry out this procedure. Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1011600EN Triton HC Version A, 04.04.2019, Index 0 Page 13...
  • Page 14: Cleaning And Disinfection Directions

    / sanitized starting as close as possible from the mains water connection (wall outlet); to make sure that also the tubing is being treated. Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1011600EN Triton HC Version A, 04.04.2019, Index 0...
  • Page 15 Should it be necessary, to open a once sanitized system again (e.g. to install a new water filter) all opened connections must be disinfected with a sanitization spray prior to reconnecting. Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1011600EN Triton HC Version A, 04.04.2019, Index 0...
  • Page 16 Please make sure the pump is in operation when the sanitizing agent is being flushed into the unit. This will ensure that all parts of the pump will come into contact with the sanitizing agent. Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1011600EN Triton HC Version A, 04.04.2019, Index 0...
  • Page 17 Depending on the unit type (Over counter dispenser / large soda circuit installation with long python runs, etc.) the amount of water that needs to be dispensed may vary. Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1011600EN Triton HC Version A, 04.04.2019, Index 0...
  • Page 18 / sanitization procedure must be documented accordingly and the documentation must remain at the cooler (this may vary depending on local regulations). Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1011600EN Triton HC Version A, 04.04.2019, Index 0...
  • Page 19: Problems And Troubleshooting

    Call service technician syrup in beverage is clamping (only post-mix) Delivery pressure for Adjust CO -pressure syrup too low or too high Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1011600EN Triton HC Version A, 04.04.2019, Index 0 Page 19...
  • Page 20: Technical Data

    Cooling capacities and output capacity at 24°C ambient temperatures and water or syrup inlet temperatures of 24°C and beverage outlet temperatures of less than 5°C. When Cornelius pythons are used, a cooling loss of 13 kcal/hour per meter length must be included in calculations.
  • Page 21: Illustration Of The Triton

     Triton HC Illustration of the Triton 11.1 Connections at the Unit Triton 150 HC Triton 350 HC Triton 350v HC Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1011600EN Triton HC Version A, 04.04.2019, Index 0 Page 21...
  • Page 22: Flow Chart

     Triton HC 11.2 Flow Chart Flow Chart Triton 150 HC Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1011600EN Triton HC Version A, 04.04.2019, Index 0 Page 22...
  • Page 23  Triton HC Flow Chart Triton 350 HC Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1011600EN Triton HC Version A, 04.04.2019, Index 0 Page 23...
  • Page 24  Triton HC Flow Chart Triton 350v HC Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1011600EN Triton HC Version A, 04.04.2019, Index 0 Page 24...
  • Page 25: Circuit Diagram

     Triton HC 11.3 Circuit Diagram Circuit Diagram Triton 150 HC 24V~ 230V~ Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1011600EN Triton HC Version A, 04.04.2019, Index 0 Page 25...
  • Page 26  Triton HC Circuit Diagram Triton 350 / 350v HC Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1011600EN Triton HC Version A, 04.04.2019, Index 0 Page 26...
  • Page 27: Exploded View / Spare Part List

     Triton HC Exploded View / Spare part list 12.1 Exploded View Exploded View Triton 150 HC Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1011600EN Triton HC Version A, 04.04.2019, Index 0 Page 27...
  • Page 28  Triton HC Exploded View Triton 350 HC Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1011600EN Triton HC Version A, 04.04.2019, Index 0 Page 28...
  • Page 29  Triton HC Exploded View Triton 350v HC Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1011600EN Triton HC Version A, 04.04.2019, Index 0 Page 29...
  • Page 30: Spare Part List

    Option RCBO for Triton 350 Not shown 220046714 Harness RCBO Not shown 220116247 Bracket RCBO Not shown 141647763 Fuse 16A-30mA RCBO Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1011600EN Triton HC Version A, 04.04.2019, Index 0 Page 30...
  • Page 31 Not shown 220046976 Cable Ice bank probe Not shown 220111270 Holder Ice Bank Probe Not shown 220106425 Water Level Float - Energize Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1011600EN Triton HC Version A, 04.04.2019, Index 0 Page 31...
  • Page 32: Declaration Of Conformity

     TRITON HC RANGE Declaration of conformity...

This manual is also suitable for:

Triton 150 hcTriton 350 hcTriton 350v hc

Table of Contents