Improper use Improper use of the unit and unauthorized modifications to the unit and its components may cause personal injury and equipment damage for which Cornelius Deutschland GmbH shall assume no liability. Improper use of the unit is prohibited. The following in particular is regarded as improper use:...
An expert must also have received technical training in the unit-specific special features of Cornelius products. The assigned tasks are always to be carried out in compliance with this manual.
Page 6
When installing cables, be mindful of any bending radiuses that the manufacturer may have specified. To fix cables in place using cable ties, use the mounting bases provided. Manual operation undercounter cooler Cornelius Deutschland GmbH Energize R134a 60Hz Document no: TD1005601EN Page 6...
Energize R134a 60Hz Transport and packaging Choose a suitable packaging when returning the unit itself or one of its components to Cornelius Deutschland GmbH, e.g. for repairs. In particular, make sure that the unit and any components are protected from shock/impact, moisture, dirt and electrostatic discharge (ESD). This will prevent transport damage to the unit and to the components, for which the manufacturer shall assume no liability.
Such fuels or lubricants must always be prevented from seeping into the ground, the sewage system and any bodies of water, and must always be prevented from entering the atmosphere. Manual operation undercounter cooler Cornelius Deutschland GmbH Energize R134a 60Hz Document no: TD1005601EN Page 8...
Required values are listed on the installation protocol of the dispense tower. These values need to be adjusted when a product line or one of its components has changed. Manual operation undercounter cooler Cornelius Deutschland GmbH Energize R134a 60Hz Document no: TD1005601EN Page 9 Version A, 24.09.2019, Index 0...
A socket outlet with an earthed contact featuring a maximum protection of 16 amperes is required. The line voltage must always be within following tolerances: 220 VAC +6%/-10% / 60 Hz Manual operation undercounter cooler Cornelius Deutschland GmbH Energize R134a 60Hz Document no: TD1005601EN Page 10 Version A, 24.09.2019, Index 0...
For the power supply of the valves these are connected to the connecting bus (see wiring diagram) at the Energizes inner panel according to the circuit diagram. Manual operation undercounter cooler Cornelius Deutschland GmbH Energize R134a 60Hz Document no: TD1005601EN Page 11 Version A, 24.09.2019, Index 0...
4.2 bar. If a different flow pressure is required the switching point of the pressure switch must be set accordingly. Refer to the circuit diagram for the connection. The flow rate of the still water should be 300 ml each 4seconds. Manual operation undercounter cooler Cornelius Deutschland GmbH Energize R134a 60Hz Document no: TD1005601EN Page 12...
20 min has been exceeded. Long run periods are signs of leaks or too large extraction. It is then only possible to turn the pump back on by a power network reset (pulling out the mains plug briefly). Manual operation undercounter cooler Cornelius Deutschland GmbH Energize R134a 60Hz Document no: TD1005601EN Page 13 Version A, 24.09.2019, Index 0...
Only trained specialists are carry out this procedure. Disposal and Environment Protection Since many years the technical designers of IMI Cornelius work together with the customers to manufacture devices which do not contain dangerous materials. They were designed in such a way that over 95% of the used materials can be easily recycled separately.
The unit should be cleaned / sanitized starting as close as possible from the mains water connection (wall outlet) to make sure that also the tubing is being treated. Manual operation undercounter cooler Cornelius Deutschland GmbH Energize R134a 60Hz Document no: TD1005601EN Page 15...
Afterwards close the CO gas and depressurize the complete system again. Manual operation undercounter cooler Cornelius Deutschland GmbH Energize R134a 60Hz Document no: TD1005601EN Page 16 Version A, 24.09.2019, Index 0...
Connect the syrup containers again to the syrup lines and dispense syrup on the post-mix valves until a consistent flow of syrup occurs again. Manual operation undercounter cooler Cornelius Deutschland GmbH Energize R134a 60Hz Document no: TD1005601EN Page 17...
Dispense from each tap a few beverages to fully put the system back into operation again. The cleaning / sanitization procedure must be documented accordingly and the documentation must remain at the cooler (this may vary depending on local regulations). Manual operation undercounter cooler Cornelius Deutschland GmbH Energize R134a 60Hz Document no: TD1005601EN Page 18...
Cooling capacity and dispense capacity at 32°C ambient temperature and 32°C water inlet respectively 32°C Syrup inlet temperature and drink temperatures of less than 5°C. We reserve the right to make modifications. Manual operation undercounter cooler Cornelius Deutschland GmbH Energize R134a 60Hz Document no: TD1005601EN Page 19...
Water level indicator Controller display Air flow Drain Air flow Energize 5 Connection plate Controller display Air flow Air flow Air flow Manual operation undercounter cooler Cornelius Deutschland GmbH Energize R134a 60Hz Document no: TD1005601EN Page 20 Version A, 24.09.2019, Index 0...
Syrup IN Energize 5 Soda Soda Water IN Cable Soda Return Soda Return Flow Flow Guidance Syrup IN Syrup OUT Manual operation undercounter cooler Cornelius Deutschland GmbH Energize R134a 60Hz Document no: TD1005601EN Page 21 Version A, 24.09.2019, Index 0...
Carbonator pump is not running Check if Carbonator pump is Note! Only with mechanical taps running, if not call service technician Manual operation undercounter cooler Cornelius Deutschland GmbH Energize R134a 60Hz Document no: TD1005601EN Page 22 Version A, 24.09.2019, Index 0...
For information only Carbonator pump run time For information only Voltage check NOK Power supply out of specification Check power supply conditions Manual operation undercounter cooler Cornelius Deutschland GmbH Energize R134a 60Hz Document no: TD1005601EN Page 23 Version A, 24.09.2019, Index 0...
Energize R134a 60Hz 13 Exploded Views and recommended spare parts 13.1 Energize 3 Manual operation undercounter cooler Cornelius Deutschland GmbH Energize R134a 60Hz Document no: TD1005601EN Page 26 Version A, 24.09.2019, Index 0...
Energize R134a 60Hz 13.3 Energize 5 Single carbonator Manual operation undercounter cooler Cornelius Deutschland GmbH Energize R134a 60Hz Document no: TD1005601EN Page 30 Version A, 24.09.2019, Index 0...
Page 31
Pressostat KP 7 W 14-7047-134 Dryer 8,1/8,1 - R134a Trockner 8,1/8,1 - R134a 22-0105-775 Probe Hot gas / Ambient Fühler Heißgas / Ambient Manual operation undercounter cooler Cornelius Deutschland GmbH Energize R134a 60Hz Document no: TD1005601EN Page 31 Version A, 24.09.2019, Index 0...
Energize R134a 60Hz 14 Declaration of Conformity Manual operation undercounter cooler Cornelius Deutschland GmbH Energize R134a 60Hz Document no: TD1005601EN Page 32 Version A, 24.09.2019, Index 0...
Page 33
Energize R134a 60Hz Manual operation undercounter cooler Cornelius Deutschland GmbH Energize R134a 60Hz Document no: TD1005601EN Page 33 Version A, 24.09.2019, Index 0...