Figure 1:Parts Identification - Cornelius Enduro ED-250 BCP Installation Manual

Cornelius ice/beverage dispenser installation manual
Hide thumbs Also See for Enduro ED-250 BCP:
Table of Contents

Advertisement

Enduro Ice/beverage Dispenser Installation Manual
7. Maximum and minimum ambient temperature rating for correct operation is 40 to 105 F
8. The dispenser is not designed for a wash down environment and must not be placed in an area where a water
jet could be used.
9. The unit has to be placed in a horizontal position.
10. If the supply cord is damaged, it must be replaced by the manufacturer, it's service agent or similarly qualified
person in order to avoid a hazard.
11. ICE PORTION CONTROLLER: Regulated CO2 gas pressure is required to operate the portion control dis-
pensing system. Proceed as follows to connect the CO2 gas pressure source line to the dispenser.
A. Connect and route the CO2 line from outlet side of the source regulator assembly up to the dispenser.
NOTE: That the minimum source-regulated pressure is 40 psig.
B. Connect the CO2 source line to dispenser inlet line labeled "CO2".
C. The dispenser regulator outlet pressure is factory preset to 34 psig  2 psig DO NOT ADJUST.
Publication Number: 620916501INS
Figure 1. Parts Identification
- 5 -
© 2001-2010, IMI Cornelius Inc.