Beckhoff KS2535, KL2545 Manual page 34

Pulse width current terminals
Table of Contents

Advertisement

Configuration software KS2000
Dithering active (R32.5 [} 45])
You can activate the dithering [} 16]here (the default is inactive).
Valve curve (R32.4 [} 45])
You can activate the valve curve [} 17]here (the default is inactive).
Process data ramps active (R32.6 [} 45])
You can activate the process data ramps [} 18] here (the default is inactive).
Register values
User offset (R33 [} 45])
You can specify the offset for the user-scaling here (the default is 0).
User gain (R34 [} 45])
The gain for the user scaling can be set here (default: 4096
).
dec
User switch-on value (R35 [} 45])
You can specify the offset for the user switch-on value for the speed here (the default is 0).
Max. output current (R36 [} 45])
You can specify the maximum output current here.
KL2535: The default is 1000 mA
KL2545: The default is 3,500 mA
Dithering frequency (R37 [} 46])
You can specify the frequency of the dither [} 16]here (the default is 0).
Dithering amplitude (R38 [} 46])
You can specify the amplitude of the dither [} 16]here (the default is 0).
Dithering switch-off ramp (R39 [} 46])
You can specify the switch-off ramp of the dither [} 16]here (the default is 0).
Overlap threshold value (R40 [} 46])
You can specify the threshold value of the overlap region [} 17]here (the default is 0).
Overlap output value (R41 [} 45])
You can specify the output value of the overlap region [} 17]here (the default is 0).
Bend threshold value (R42 [} 46])
You can specify the threshold value of the bend compensation region [} 17] here (the default is 0).
34
Version: 2.1.0
KL2535/KS2535, KL2545/KS2545