Installing The Air Compressor - Sullair SRL-7.5MB User Manual

Oil free scroll compressor
Table of Contents

Advertisement

Subject to EAR, ECCN EAR99 and related export control restrictions.
Installation(continued)

3 Installing the Air Compressor

1. Install the air compressor inside a room with adequate space, ventilation and relatively low humidity.
2. Keep the operating room temperature between 32°F and 104°F (0°C and 40°C).
3. Install the air compressor with the recommended spacing shown in the figure below for ease of
maintenance and temperature control.
・The air compressor is designed to intake air from the left side of the package and exhaust the air out
of the top of the package. Provide suction and exhaust openings as shown in the figure below to
properly ventilate the room. If the suction and exhaust openings cannot be provided, do not modify
the air compressor without consulting the local Sullair distributor.
4. The allotted space located to the right and to the rear of the air compressor must be maintained
to perform maintenance. Ensure that this space is maintained if the air compressor is going to be
permanently installed. (#)
Ventilating fan
● If the temperature exceeds 104°F (40°C) in
the room, install a ventilating fan to keep
the room temperature below 104°F (40°C).
● Select a ventilating fan with enough
capacity to handle the air flow of the room.
Intake Opening
● The intake opening should be installed as
low as possible. The area of the opening
should be calculated as 1,550 sq in.(1m
per compressor.
● Conditions of the ambient air, including
dust and toxic substances, should be
considered when selecting the location
for the intake air opening.
【Reference 】
■ Guidance for construction of ventilating fan and exhaust duct
Exhaust Air
of air
compressor
Intake Air
Exhaust
Opening
Exhaust
air
20 in. (508 mm)
or more (#)
Intake
Opening
25 in. (635 mm)
or more
2
)
● Secure enough space for proper ventilation.
● Absence of intake space causes the suction resistance to
● Secure enough space for wiring and piping.
A
Exhaust Air
■ Ventilating Fan
Refer to the volume of
necessary ventilation (1).
Exhaust duct
● Do not directly connect the duct with the
air compressor. The ducting hood should
maintain a distance (indicated as "h")
between the air compressor and the duct
that is larger than the diameter of the duct.
40 in. (1016 mm)
or more
h
12 in. (305 mm)
or more (#)
40 in. (1016 mm)
or more
Maintenance Space,
Intake Air, Discharge
Piping and Wiring
increase, resulting in temperature rise in the package, which may
cause a reduction in the life of air compressor components.
B
E x h a u s t
Duct
Intake Air
5
02250236-267 R02
Ventilation and
Exhaust Space
● Secure enough space for proper
ventilation.
● Absence of intake space causes
the suction resistance to increase,
resulting in temperature rise in the
package, which may cause a
reduction in the life of air
compressor components.
Maintenance Space for
Right & Rear Sides
● If a space of more than 12 in
(305 mm) for the right side and
20 in (508 mm) for the rear
cannot be secured, utilize a piping
connection that can be easily
removed for maintenance.
Front Maintenance Space
● Secure the proper amount of
space to open the front door of
the air compressor for inspection.
■ Ventilating Fan
Refer to the volume of
necessary ventilation (2).