02250236-267 R02
Operation (continued)
Automatic recovery from power failure does not function under default settings.
It is possible to set automatic recovery from power failure by using the control panel.
Digital Display
Operate the switches on the control panel as shown below in order to automatically recover from power
failure.
1 Verify if the pressure is indicated on the digital display.
Press and hold the stop switch for three seconds.
2
"P-0" is indicated on the digital display.
Press and hold the start switch until "P-1" is indicated on the digital
3
dispiay and power failure automatic recovery is set.
To cancel the power failure automatic recovery, carry out steps 1 to 3
4
to indicate "P-1" to "P-0" on the digital display.
5 Pressure is again indicated on the digital display after three seconds.
NOTE: Even if the power failure automatic recovery has not been set, the pressure indication will
return to the digital display after three seconds.
● When operating in automatic power recovery, the air compressor will start automatically when the
main power supply returns. Make sure to press the Stop switch before turning off the main power
supply when conducting maintenance.
● In the case of a power failure, turn off the main power supply. Be aware that residual pressure may
exist even though there is not a digital display.
● When restarting the operation of the air compressor, turn on the main power supply and verify the
operation control mode before pressing the Start switch.
Subject to EAR, ECCN EAR99 and related export control restrictions.
Start Switch
Steps
WARNING
18
Stop Switch
Digital Display