Operation (continued)
Standard
[STOP]
Maximum
Pressure
[122psig (8.4 bar)/
145psig (10.0 bar)]
T h e m a x i m u m
( S t o p ) P r e s s u r e
setting has been
c h a n g e d o n t h e
control panel of the
air compressor.
Standard
[START]
Recovery
Pressure
[110psig (7.6 bar)/
115psig (7.9 bar)]
The recovery (Start)
P r e s s u r e s e t t i n g
has been changed
o n t h e c o n t r o l
p a n e l o f t h e a i r
compressor.
● As the protection device extends the ON-OFF cycle, the discharge pressure may exceed the
maximum pressure setting. This is not an error.
20sec.
20sec.
20sec.
or more
ON-OFF
Extend ON-OFF
cycle
cycle
CAUTION
17
Once
2nd
3rd
20sec.
20sec.
20sec.
20sec.
or less
or less
or less
or less
Start Frequency
Being Measured
"ON-OFF cycle error"
occurs