OPERATING PROCEDURES

Daily Cleaning Procedures

Left Grill Surface and Platen
1. Double press the green button to place the platen in
standby mode. See Figure 6-2
CAUTION! The upper platen surface and
release sheet are very hot. To prevent burn injuries, wear
heat-resistant gloves when replacing the release sheets.
6
2. With the platen closed, unclip the front and side
release sheet clips. Place these clips in a 1/9 size
pan partially filled with water. See Figure
Repeat clip removal procedure for all additional plat-
ens.
6-2
Figure 6-2
Figure 6-3
Model L850, L852, L858 Series
3. Select the Full Clean mode from the Clean menu.
See Figure 6-4
Figure 6-4
4. Remove rear splash guard and set it aside to be
taken to the sink later to be washed, rinsed, and
sanitized. See Figure 6-5
Figure 6-5
5. Apply Hi-Temp Cleaner directly to the grill surface.
Spread with the blue-handled angle tool. See
Figure 6-6