PROGRAMMING
SIREN AND ALARMS
Setting
Burglary Alarm Confirmation Timer
Fire Verification
PowerG Smoke Detector Siren
Severe Weather Siren Warning
Dialer Delay
NOTE: Shall not be used on EN Grade 2
Siren Timeout
Default
Timer used for Burglary Alarm Confirmation.
60
Grade 2 is enabled.
When enabled, panel requires two fire events from smoke detector (one detector twice or
Disabled
two detectors once each)
NOTE: Not allowed on UL/cUL installations
When set to "Fire Alarms Only", PowerG Smoke Detectors that are learned into the
Fire Alarms Only
system will only sound during fire alarm events. When set to "All Alarms", PowerG Smoke
Detectors will act as additional wireless sirens and will sound during all alarm events.
When enabled, siren will sound when the panel receives a severe weather alert. When
Enabled
disabled, panel will use severe weather chime
Amount of time (in seconds) before panel will attempt call to central station after an alarm
event is triggered
:30
When SIA Limits enabled: :15 to :45 seconds
When SIA Limits disabled: :0 to :254 seconds
Determine how long before siren stops sounding during an alarm event (4 minutes to 15
minutes).
NOTE: For UL/cUL residential fire/burg applications the minimum bell timeout shall be set to 5 min. For
4 min
UL Commercial Burglary installations, minimum bell time out shall be set to 15 minutes. For EN Grade 2 the minimum
bell timeout shall be 90 sec and maximum bell timeout shall not exceed local regulations.
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE
Description
77
OF
158
NOTE: This setting is greyed out and unavailable unless EN