Technical data
Taurus 301
8
Technical data
Performance specifications and guarantee only in connection with original spare and
replacement parts!
8.1
Taurus 301
Welding current/voltage setting range:
TIG
MMA
MIG/MAG
Duty cycle at 25 °C
80%
100%
Duty cycle at 40 °C
60%
100%
Load alternation
Open circuit voltage
Mains voltage (tolerances)
Frequency
Mains fuse (slow-blow safety fuse)
Mains connection lead
Max. connected power
MIG/MAG
TIG
MMA
Recommended generator rating
Cosϕ
Insulation class/protection classification
Ambient temperature
Machine/torch cooling
Workpiece lead
Dimensions L/W/H [mm]
Weight
Wire-feed speed
Standard WF roller fitting
WF drive unit
Torch connection
EMC class
Constructed to standards
88
NOTE
5 A/10.2 V-300 A/22.0 V
5 A/20.2 V-300 A/32.0 V
5 A/14.3 V-300 A/29.0 V
300 A
270 A
300 A
250 A
∧
10 min (60% ED
6 min. welding, 4 min. break)
3 x 400 V (-25% to +20%)
50/60 Hz
3x16 A
H07RN-F4G4
11 kVA
8.3 kVA
12.1 kVA
16.4 kVA
H/IP 23
-20 °C to +40 °C
Fan/gas
930 x 460 x 730
0.5 m/min to 24 m/min
0.8 + 1.0mm (for steel wire)
4-roller (37mm)
Welding torch central connection (Euro)
IEC 60974-1, -5, -10 /
98 V
0.99
50m²
79 kg
A
/
099-005157-EW501
09.06.2011
Need help?