Non-latched mode
I
Selection
Select non-latched operating mode
Step 1
Press and hold torch trigger.
Shielding gas is expelled (gas pre-flows).
The arc is ignited using liftarc.
Welding current flows with pre-selected setting.
Step 2
Release torch trigger.
Arc is extinguished.
Gas post-flow time elapses.
Special, non-latched
I
Selection
Select non-latched special mode
Step 1
Press and hold torch trigger
Shielding gas is expelled (gas pre-flows)
The arc is ignited using liftarc.
Welding gas flows with pre-selected setting in start program "P
After the "tstart" ignition current time elapses, the welding current rises with the set upslope time "tS1"
to the main program "P
Step 2
Release torch trigger.
The welding current reduces with the downslope time "tSe" to the end program "P
After the end current time "end" elapses, the arc will extinguish.
Gas post-flow time elapses.
099-005157-EW501
09.06.2011
1.
Figure 5-39
.
1.
P
START
Figure 5-40
.
".
A
Design and function
P
A
P
A
".
START
TIG welding
2.
t
t
2.
t
P
END
t
".
END