Allen-Bradley Micro800 2080-MEMBAK-RTC2 User Manual page 67

Plug-in modules
Table of Contents

Advertisement

Rockwell Automation Publication 2080-UM004D-EN-E - March 2018
Transaction Block Format
Byte Offset
Contents
0
Status
1
Transaction ID
2
Size
3
Reserved
4
MAC ID
5
Service
6...115
Transaction Body (110 bytes)
Explicit Message Request Format
Byte Offset
Contents
0
Status
1
Transaction ID
2
Size
3
Reserved
4
MAC ID
5
Service
6...7
Class
8...9
Instance
10...115
Service Data (106 Bytes)
Explicit Message Response Format
Byte Offset
Contents
0
Status
1
Transaction ID
2
Size
3
Reserved
4
MAC ID
5
Service
Byte Offset
Contents
0
Status
6...115
ServiceData
Explicit Message Status Codes
Status Code
0
DeviceNet Plug-in – 2080-DNET20
Request Data
Can be read from UDFB status
Can be read from UDFB response data.
Response data shows CIP error Code.
Description
Ignore transaction block (block empty).
Chapter 5
57

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Micro800 2080-iq4ob4Micro800 2080-iq4ov4Micro800 2080-ob4Micro800 2080-ov4Micro800 2080-ow4iMicro800 2080-if2 ... Show all