DeviceNet Plug-in – 2080-DNET20
54
RA_PF_DNET_MULTIDRIVE: Input and Output Parameters
Variable Name
Type
FBEN
INPUT
PlcPortNum
INPUT
NodeNum
INPUT
Start
INPUT
Stop
INPUT
ReferenceSpeed
INPUT
Jog
INPUT
ClearFault
INPUT
Fwd_Rev
INPUT
FBENO
OUTPUT
PF_Feedback
OUTPUT
PF_Ready
OUTPUT
PF_Active
OUTPUT
Data Type
Description
BOOL
Function block enable input.
TRUE to enable the function.
UINT
Plug-in slot number (1...5 for plug-in slots).
USINT
DeviceNet node address for PowerFlex drive
(connected as master in multi-drive setup).
BOOL[1...5]
TRUE to start each element of the array.
Corresponds to each drive.
For example: Start[1] for Drive 1 and Start[5] for
Drive5.
BOOL[1...5]
TRUE to stop each element of the array.
Corresponds to each drive, for example, Stop
[1] for Drive 1 and Stop [5] for Drive5.
REA[1...5]L
Reference speed to set the device speed.
Each element of the array corresponds to each
drive, for example, Reference Speed [1]
for Drive 1 and Reference Speed [5] for Drive5.
BOOL[1...5]
TRUE to enable jog in PowerFlex drive.
Each element of the array corresponds to each
drive, for example, Reference Jog [1] for Drive
1 and Jog [5] for Drive5.
BOOL[1...5]
TRUE to clear fault in PowerFlex drive.
Each element of the array corresponds to each
drive, for example, ClearFault [1] for Drive 1
and ClearFault [5] for Drive5.
BOOL[1...5]
TRUE to configure PowerFlex drive for forward
motion.
FALSE to configure PowerFlex drive for Reverse
motion.
Each element of the array corresponds to each
drive, for example, Fwd_Rev [1] for Drive 1 and
Fwd_Rev [5] for Drive5.
BOOL
Function block enable output.
TRUE upon exit.
REAL[1...5]
Speed reference from the PowerFlex drive.
Each element of the array corresponds to each
drive, for example, PF_Feedback[1] for Drive 1
and PF_Feedback[5] for Drive5.
BOOL[1...5]
Ready bit from PowerFlex drive.
Each element of the array corresponds to each
drive, for example, PF_Ready[1] for Drive 1 and
PF_Ready[5] for Drive5.
BOOL[1...5]
Active bit from PowerFlex drive.
Each element of the array corresponds to each
drive, for example, PF_Active[1] for Drive 1 and
PF_Active[5] for Drive5.