Lenord+Bauer
8
Removal
Magnetic field!
WARNING
●
Ensure that there is at least 30 cm spacing between the implants
and the products.
Magnetic field!
CAUTION
●
Hold the MiniCODER in such a way as to avoid crushing of fingers
or skin.
If a functional MiniCODER is to be removed for a modification, pay attention to the
following:
– Ensure the sensitive measuring surface does not come into contact with other
objects to prevent damage.
– Only touch the connector pins and wires if you are suitably earthed, for example
using an ESD wrist strap, to prevent damage to the electronic components due to
electrostatic discharge.
GEL 2444K P
If a testing and programming unit GEL 211CS0 is available, reset the MiniCODER
to the factory settings.
Switch off the power supply.
Disconnect the connection.
Uncover the connection cable.
Insert the distance gauge in the air gap.
NOTICE
Handling!
Avoid impacts against the measuring surface by other objects.
Undo and remove the screws for the MiniCODER.
Take the MiniCODER out of the mounting.
If the MiniCODER is to be used again, store it in the original packaging or an
equivalent container with protection.
GEL 2444
:
8 Removal
67