Removal

Magnetic field!
WARNING
Ensure that there is at least 30 cm spacing between the implants
and the products.
Magnetic field!
CAUTION
Hold the MiniCODER in such a way as to avoid crushing of fingers
or skin.
If a functional MiniCODER is to be removed for a modification, pay attention to the
following:
– Ensure the sensitive measuring surface does not come into contact with other
objects to prevent damage.
– Only touch the connector pins and wires if you are suitably earthed, for example
using an ESD wrist strap, to prevent damage to the electronic components due to
electrostatic discharge.
 GEL 2444K P
If a testing and programming unit GEL 211CS0 is available, reset the MiniCODER
to the factory settings.
 Switch off the power supply.
 Disconnect the connection.
 Uncover the connection cable.
 Insert the distance gauge in the air gap.
NOTICE
Handling!
Avoid impacts against the measuring surface by other objects.
 Undo and remove the screws for the MiniCODER.
 Take the MiniCODER out of the mounting.
 If the MiniCODER is to be used again, store it in the original packaging or an
equivalent container with protection.
GEL 2444
:
8 Removal
67

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MiniCODER GEL 2444K Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Minicoder gel 2444d seriesMinicoder gel 2444t seriesMinicoder gel 2444Minicoder gel 2444 k pg

Table of Contents