4. Safety

Power supply to Mini Master must be terminated when the pool circulation stops. Otherwise, there is a risk that water runs back
into the system (depending on the system design or the level differences between the pool and the engine room).
At backwashing and cleaning of the sand filters, water measuring to MiniMaster should be always shut down.
To minimize the risk of corrosion, all dosing units should be placed after all other equipment . The dosing points for liquid acid
and chlorine should be as far apart as possible in the circulatory system, but at least 500 mm from each other, and CHLORINE
DOSING ALWAYS LAST, see Fig. 2.
Handling of chemical agents
Liquid chlorine and liquid acid are harsh chemicals with basic respective acidic properties.
They SHOULD NOT BE mixed with each other, since this may cause severe chemical reactions.
Different chemical containers must be placed well apart from each other and stay in its own vessel in order
to accommodate the entire chemical container volume.
When handling those chemicals, use protective equipment, like gloves, apron and goggles.

5. Dimensions

6. Installation
1
5
2
6
VISE
MiniMaster
MiniMaster
416600, 416610, 416620, 416630 - M11278-11
ph + Chlorine or ph + Redox
33034, 33035, 33036
85
83
3
-
+
5
4
8
10
7
9
12
MiniMaster
Chlorine or pH
310
310
260
260
14
16
17
18
13
19
11
12
4
ENGLISH
310
310
260
260
1. Skimmer
2. Main drain
3. Inlet
4. JetSwim
5. Light
6. Pool circulation pump
7. Filter
8. Heat exchanger
9. Check valve
15
10. Circulation pump heat
11. Heat source
12. Drain
13. Check valve (optional)
14. MiniMaster
15. Prefilter MiniMaster
16. Chlorine dosing
17. Chlorine
18. Acid/alkali dosing
19. Acid/alkali
M11291-15
2022-07-12 ASA
!
Fig. 1.
Fig. 2.