2. Hydraulic filters

IMPORTANT
ALWAYS REPLACE BOTH FILTERS AT THE SAME TIME.
Pressure Filter
Interval - After first 50 hours of operation and
every 250 hours thereafter.
.
• Position
the
Selector Switch to "O" position.
• Activate the release valve (located at
the front side of the machine) to release
the pressure in the hydraulic circuit
(position the release valve lever to
"release position" (
• Unscrew the filter container.
HIGH PRESSURE OIL COULD PENETRATE SKIN AND CAUSE
INJURIES OR BURNS.
LOOSEN THE FILTER TANK VERY SLOWLY TO ALLOW THE OIL
PRESSURE TO DROP GRADUALLY.
NOTE: Use a container to collect the oil from the hydraulic
lines or from the filter and prevent it from spilling on
the work platform or on the ground.
• Install a new filter cartridge.
• Install the filter container.
31210005
SECTION 8 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
LOW TEMPE RATURE
DOWN - 35°C
NERVO L - EQUIVIS XV 32
NERVO L - HY DRELF XV 32
FO OD COMP ATIBLE
LOW TEMPE RATURE
NERVOL - AGROFLUID
LOW TEMPE RATURE
DOWN - 35°C
NERVO L - CRYO GREAS E
MOBILITH S HC 220
Platform/Off/Ground
).
S TANDARD
C
MOBILTAC 81
S TANDARD
D
MOBIL DTE 16M
CHAINE FILANTE
S TANDARD
E
MOBILUX EP 2
CO MPLEX EP2
Return Filter
Interval - After first 50 hours of operation and
every 250 hours thereafter.
• Position
Selector Switch to "O" position.
• Remove the return filter cap and remove
the spring.
• Replace the filter cartridge with a new
one.
• Check the presence and condition of the
O ring, close the filter cover. Do not
forget to install the spring.
AFTER INSTALLATION, PERFORM A FEW MOVEMENTS TO
BLEED THE AIR FROM THE HYDRAULIC CIRCUIT, CHECK THE
OIL LEVEL IN THE TANK (PLATFORM IN RETRACTED POSITION).
NOTE: Used oils and cartridges must be disposed of
according to regulations in force.
NOTE: Aside from JLG recommendations, it is not
advisable to mix oils of different brands or types, as
they may not contain the same required additives or
be of comparable viscosities. If use of hydraulic oil
or grease other than recommended in the previous
chart,
contact
recommendations.
L U B R I C AT I O N I N T E R VA L S A R E B A S E D O N M A C H I N E
OPERATION UNDER NORMAL CONDITIONS. FOR MACHINES
U S E D I N M U L T I - S H I F T O P E R AT I O N S A N D / O R S E V E R E
E N V I R O N M E N T S , L U B R I C A T I O N F R E Q U E N C Y M U S T B E
INCREASED ACCORDINGLY.
– JLG Lift –
LOW TEMPERATURE
DO WN -3 5°C
HY DRELF XV 32
the
Platform/Off/Ground
IMPORTANT
JLG
Industries
IMPORTANT
for
proper
8-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Toucan 1010

Table of Contents