Assembly

4.3 Mounting the sensor

4.3.1 Programmable magnetic switch MMS 30

18
NOTE
Observe the assembly and operating manual of the sensor for
mounting and connecting.
The product is prepared for the use of sensors.
For the exact type designations of suitable sensors, please see
l
catalog datasheet and Link Übersicht Sensoren.
For technical data for the suitable sensors, see assembly and
l
operating manual and catalog datasheet.
– The assembly and operating manual and catalog
datasheet are included in the scope of delivery for the
sensors and are available at schunk.com.
Information on handling sensors is available at schunk.com or
l
from SCHUNK contact persons.
CAUTION
Sensor can be damaged during assembly.
Observe the maximal tightening torque of 30 Ncm.
NOTE
Ferromagnetic material changes the switching positions of the
sensor. For example: Adapter plate made of ordinary steel.
At ferromagnetic adapter plates:
First mount the product on the adapter plate.
l
Then set the position of the magnetic switch.
l
brown
black
blue
04.00 | SPG 100 | Assembly and Operating Manual | en | 0389423
closer
load