20
NOTE
Observe the assembly and operating manual of the sensor for
mounting and connecting.
The product is prepared for the use of sensors.
For the exact type designations of suitable sensors, please see
l
catalog datasheet and
For technical data for the suitable sensors, see assembly and
l
operating manual and catalog datasheet.
– The assembly and operating manual and catalog
datasheet are included in the scope of delivery for the
sensors and are available at schunk.com.
Information on handling sensors is available at schunk.com or
l
from SCHUNK contact persons.
Designation
Programmable magnetic switch
MMS-P 22
CAUTION
Risk of damage to the sensor during assembly!
Observe the maximal tightening torque.
l
NOTE
Ferromagnetic components, e.g. adapter plates made of mild
steel, change the switching positions of the sensor.
For ferromagnetic adapter plates:
First, install the TCU-P on the adapter plate.
l
Then adjust position of the sensors.
l
1.
Slide sensor (1) into the groove as far as the stop (2).
OR: If there is no stop present, adjust the projection of sensor
l1 or l2, see the "Setting dimensions" table.
2.
Secure the sensor (1) using the set-screw.
Tightening torque: 10 Ncm
[/ 20].
} 4.4.1
06.00 | TCU-P | Assembly and Operating Manual | en | 389462