9. Remove the plug from one of the two locations circled in red in Figure 9, "Connecting RCM - Sprayer to
ISOBUS (Drawing)," on the CANbus Hub in the base of the ECU cabinet.
10. Locate the connector X0150 labeled RVN CAN to RVN Node on the CANbus Hub and move it to the open
connection where the plug was removed in the previous step. Replace the plug in this location. This will
connect the RCM - Sprayer to the ISObus.
FIGURE 9. Connecting RCM - Sprayer to ISOBUS (Drawing)
FIGURE 10. Connecting RCM - Sprayer to ISOBUS (Picture)
Install the Hawkeye® 2 RCM - Sprayer: RCM - Sprayer Installation
INSTALL THE HAWKEYE® 2 RCM - SPRAYER
Swap
Swap
39