which carrier board connectors are used (5mm and 10mm height are available)
which cooling solution is used. The height of the cooling solution is not specified in the COM-HPC
specification
Figure 7: Module and Carrier Height with 10mm and 5mm connector height
3.8.3 Heatspreader Plate Assembly Dimension
Please check our
Customer Section
3.9 Environmental Specification
The COMh-caRP support commercial temperature grades with on option of extended temperature
grades (E1). The E1 is only available for customized versions only.
Environmental
Operating
Commercial Grade
Non-operating -30°C to +85°C (-22°F to 185°F)
Operating
Extended Grade (E1)
Non-operating -30°C to +85°C (-22°F to 185°F)
Relative Humidity
Shock
(according to IEC / EN 60068-2-27)
Vibration
(according to IEC / EN 60068-2-6)
Table 32: Environmental Specification
www.kontron.com
for Heatspreader 3D models and drawings.
Description
0°C to +60°C (32°F to 140°F)
-25°C to +75°C (-13°F to 167°F)
93 % @40°C, non-condensing
Non-operating shock test (half-sinusoidal, 11ms, 15g)
Non-operating vibration (sinusoidal, 10 Hz to 2000 Hz, +/- 0.15 mm, 2 g)
COMh-caRP User Guide
34/60