Terminal Connection Diagram - Mitsubishi Electric FR-E720-0.1 K Instruction Manual

Table of Contents

Advertisement

Wiring
2.1
Wiring
2.1.1

Terminal connection diagram

Sink logic
Main circuit terminal
Control circuit terminal
Single-phase power input
MCCB
Single-phase
AC power
supply
MCCB
Three-phase
AC power
supply
Control input signals (No voltage input allowed)
Forward
Terminal functions vary
rotation start
with the input terminal
Reverse
assignment (Pr. 178 to
rotation start
Pr. 184)
Multi-speed selection
*2 When using terminals PC-
SD as a 24VDC power
supply, take care not to
short across terminals
PC-SD.
Contact input common
24VDC power supply
(Common for external power supply transistor)
Frequency setting signals (Analog)
*3 Terminal input specifications
can be changed by analog
input specifications
switchover (Pr. 73).
*4 Terminal input
specifications can be
changed by analog input
specifications switchover
(Pr. 267). Set the
voltage/current input
switch in the "V" position
to select voltage input (0
to 5V/0 to10V) and "I"
(initial value) to select
current input (4 to 20mA).
*5 It is recommended to use 2W1kΩ
when the frequency setting signal
is changed frequently.
NOTE
To prevent a malfunction caused by noise, separate the signal cables more than 10cm from the power cables. Also
separate the main circuit wire of the input side and the output side.
After wiring, wire offcuts must not be left in the inverter.
Wire offcuts can cause an alarm, failure or malfunction. Always keep the inverter clean. When drilling mounting holes
in an enclosure etc., take care not to allow chips and other foreign matter to enter the inverter.
The output of the single-phase power input specification is three-phase 200V.
14
*
1. DC reactor (FR-HEL)
When connecting a DC reactor, remove the
jumper across P1 and P/+
Not available for single-phase 100V power
input model.
MC
R/L1
Earth
S/L2
(Ground)
MC
R/L1
S/L2
T/L3
Earth
(Ground)
STF
STR
RH
High
speed
RM
Middle
speed
RL
Low
speed
MRS
Output
stop
RES
Reset
SD
PC
10(+5V)
3
Frequency
setting
2 0 to 5VDC
2
potentiometer
(0 to 10VDC)
1/2W1kΩ
*5
5(Analog common)
1
Terminal 4
(+)
input
4 4 to 20mADC
(Current
(-)
input)
I
Voltage/current
input switch
Connector for
plug-in option connection
Brake unit
(Option)
*1
R
*8
PR N/-
Jumper
*7
P1
P/+
*6
Inrush current
limit circuit
Main circuit
Control circuit
24V
*2
*3
PU
connector
0 to 5VDC
USB
*4
0 to 10VDC
connector
V
*4
Option connector
*6 Terminal P1 is not available for single-
phase 100V power input model.
*7 A brake transistor is not built-in to the 0.1K
and 0.2K.
*8 Brake resistor (FR-ABR, MRS, MYS type)
Install a thermal relay to prevent an
overheat and burnout of the brake resistor.
(The brake resistor can not be connected
to the 0.1K and 0.2K.)
V
W
Standard control terminal block
Relay output
C
Terminal functions vary
B
by Pr. 192 A,B,C terminal
Relay output
function selection
(Fault output)
A
Open collector output
Terminal functions vary with
RUN
the output terminal assignment
Running
(Pr. 190 and Pr. 191)
FU
Frequency detection
Open collector output common
SE
Sink/source common
Calibration resistor
Indicator
(Frequency meter, etc.)
+
-
Moving-coil type
FM
1mA full-scale
*9
SD
*9 It is not necessary when
calibrating the indicator
from the operation panel.
Motor
IM
Earth (Ground)