Misoperation prevention and parameter setting restriction

4.18.2 Parameter write disable selection (Pr. 77)

You can select whether write to various parameters can be performed or not. Use this function to prevent parameter
values from being rewritten by misoperation.
Parameter
Number
77
Parameter write selection
The above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 183)
Pr. 77 can be always set independently of the operation mode and operation status.
(1) Write parameters only during stop (setting "0" initial value)
Parameters can be written only during a stop in the PU operation mode.
The shaded parameters in the parameter list (page 58) can always be written regardless of the operation mode and
operating status. However, Pr. 72 PWM frequency selection and Pr. 240 Soft-PWM operation selection can be written when the
inverter is running in the PU operation mode, but cannot be written in the External operation mode.
(2) Inhibit parameter write (setting "1")
Parameter write is not enabled.
(Read is enabled.)
Parameter clear and all parameter clear cannot be
performed, either.
The parameters given on the right can be written if Pr. 77 =
"1".
(3) Write parameters during operation (setting "2")
Parameters can always be written.
The following prameters cannot be written when the inverter is running if Pr. 77 = "2". Stop the inverter when changing their
parameter settings.
Parameter
Number
19
Base frequency voltage
Stall prevention operation level compensation
23
factor at double speed
40
RUN key rotation direction selection
48
Second stall prevention operation current
60
Energy saving control selection
61
Reference current
Stall prevention operation reduction starting
66
frequency
71
Applied motor
79
Operation mode selection
80
Motor capacity
81
Number of motor poles
82
Motor excitation current
83
Rated motor voltage
84
Rated motor frequency
90 to 94
(Motor constants)
96
Auto tuning setting/status
178 to 184
(input terminal function selection)
190 to 192
(output terminal function selection)
Parameters referred to
Pr. 79 Operation mode selection
182
Name
Initial Value
Name
Refer to page 186
Setting Range
0
1
0
2
Parameter
Number
22
75
77
79
160
Parameter
Number
255
Life alarm status display
256
Inrush current limit circuit life display
257
Control circuit capacitor life display
258
Main circuit capacitor life display
277
Stall prevention operation current switchover
292
Automatic acceleration/deceleration
293
Acceleration/deceleration separate selection
298
Frequency search gain
Digital input unit selection
329
(Parameter for the plug-in option FR-A7AX E kit)
343
Communication error count
450
Second applied motor
Frequency command sign selection (CC-Link)
541
(Parameter for the plug-in option FR-A7NC E kit)
563
Energization time carrying-over times
564
Operating time carrying-over times
800
Control method selection
859
Torque current
Description
Write is enabled only during a stop.
Parameter can not be written.
Parameter write is enabled in any operation
mode regardless of operation status.
Name
Stall prevention operation level
Reset selection/disconnected PU detection/
PU stop selection
Parameter write selection
Operation mode selection
User group read selection
Name