Mitsubishi Electric FR-E720-0.1 K Instruction Manual page 77

Table of Contents

Advertisement

Parameter list
Func-
Parameter
Name
tion
C0
FM terminal calibration
(900)
∗8
C1
AM terminal calibration
(901)
∗8
C2
Terminal 2 frequency setting bias
(902)
frequency
∗8
C3
Terminal 2 frequency setting bias
(902)
∗8
125
Terminal 2 frequency setting gain
(903)
∗8
frequency
C4
Terminal 2 frequency setting gain
(903)
∗8
C5
Terminal 4 frequency setting bias
(904)
frequency
∗8
C6
Terminal 4 frequency setting bias
(904)
∗8
126
Terminal 4 frequency setting gain
(905)
frequency
∗8
C7
Terminal 4 frequency setting gain
(905)
∗8
C22
Frequency setting voltage bias
(922)
frequency (built-in potentiometer)
∗7∗8
C23
Frequency setting voltage bias (built-in
(922)
potentiometer)
∗7∗8
C24
Frequency setting voltage gain
(923)
frequency (built-in potentiometer)
∗7∗8
C25
Frequency setting voltage gain (built-in
(923)
potentiometer)
∗7 ∗8
990
PU buzzer control
991
PU contrast adjustment
Pr.CL
Parameter clear
ALLC
All parameter clear
Er.CL
Faults history clear
Pr.CH
Initial value change list
∗1
Differ according to capacities.
6%: 0.75K or less
4%: 1.5K to 3.7K
3%: 5.5K, 7.5K
2%: 11K, 15K
∗2
Differ according to capacities.
5s: 3.7K or less
10s: 5.5K, 7.5K
15s: 11K, 15K
∗3
Differ according to capacities.
6%: 0.1K, 0.2K
4%: 0.4K to 7.5K
2%: 11K, 15K
∗4
Write is disabled in the communication mode (network operation mode) from the PU connector.
∗5
The initial value differs according to the voltage class. (100V, 200V class/400V class)
∗6
The range differs according to the Pr. 71 setting.
∗7
Set this parameter when calibrating the operation panel built-in potentiometer for the FR-E500 series operation panel (PA02) connected with cable.
∗8
The parameter number in parentheses is the one for use with the operation panel (PA02) for the FR-E500 series or parameter unit (FR-PU04/FR-PU07).
∗9
These parameters are communication parameters that are not cleared when parameter clear (all clear) is executed from RS-485 communication. (Refer to
page 206 for RS-485 communication) Note that when using a three-phase power input specification model, Pr.345 and Pr.346 are set back to initial values.
∗10 Available only for the three-phase power input specification model.
74
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
155
0 to 400Hz
0.01Hz
0Hz
174
0 to 300%
0.1%
0%
174
0 to 400Hz
0.01Hz
60Hz
174
0 to 300%
0.1%
100%
174
0 to 400Hz
0.01Hz
0Hz
174
0 to 300%
0.1%
20%
174
0 to 400Hz
0.01Hz
60Hz
174
0 to 300%
0.1%
100%
174
0 to 400Hz
0.01Hz
0
267
0 to 300%
0.1%
0
267
0 to 400Hz
0.01Hz
60Hz
267
0 to 300%
0.1%
100%
267
0, 1
1
1
265
0 to 63
1
58
265
0, 1
1
0
273
0, 1
1
0
273
0, 1
1
0
275
274
Customer
Parameter
Remarks
Setting
C0
(900)
C1
(901)
C2
(902)
C3
(902)
125
(903)
C4
(903)
C5
(904)
C6
(904)
126
(905)
C7
(905)
C22
(922)
C23
(922)
C24
(923)
C25
(923)
990
991
Pr.CL
ALLC
Er.CL
Pr.CH
Control Mode-based
Instruction Code
Correspondence Table
Read
Write
Extended
V/F
V/F
V/F
AD MFVC
AD MFVC
AD MFVC
GP MFVC
GP MFVC
GP MFVC
5C
DC
1
5D
DD
1
5E
DE
1
5E
DE
1
5F
DF
1
5F
DF
1
60
E0
1
60
E0
1
61
E1
1
61
E1
1
16
96
9
16
96
9
17
97
9
17
97
9
5A
DA
9
5B
DB
9
FC
FC
F4
Parameter list
Parameter
Copy
Clear
All clear
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents