Mitsubishi Electric FR-E720-0.1 K Instruction Manual page 28

Table of Contents

Advertisement

Single-phase 200V class
FR-E720S-0.1K to 0.4K
Screw size (M3.5)
N/-
R/L1 S/L2
Screw size
(M3.5)
Power supply
Single-phase 100V class
FR-E710W-0.1K to 0.4K
Screw size (M3.5)
N/-
R/L1 S/L2
Screw size
(M3.5)
Power supply
NOTE
Make sure the power cables are connected to the R/L1, S/L2, T/L3. (Phase need not be matched.) Never connect the
power cable to the U, V, W of the inverter. Doing so will damage the inverter.
Connect the motor to U, V, W. Turning ON the forward rotation switch (signal) at this time rotates the motor
counterclockwise when viewed from the load shaft.
Jumper
P/+
PR
IM
Motor
Jumper
P/+
PR
IM
Motor
Main circuit terminal specifications
FR-E720S-0.75K to 2.2K
Jumper
N/- P/+
Screw size (M4)
R/L1 S/L2
PR
Power supply
FR-E710W-0.75K
Jumper
N/- P/+
Screw size (M4)
R/L1 S/L2
PR
Power supply
IM
Screw size
(M4)
Motor
IM
Screw size
(M4)
Motor
17
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents