ERROR CODES
ERROR CODES
Accelerometer Err
Accelerometer ID Error
Ballast Fault_1
Ballast Fault_2
Ballast Fault_3
Ballast Fault_4
Ballast Fault_5
Ballast Fault_6
Ballast Fault_8
Ballast Fault_Other
BallastWasOver Hot
Ballast_Uart_Fail
ShiftFanFault
Pan Reset Fail
Tilt Reset Fail
REPLACE THE LAMP
Excess Humidity
Humidity Warning
2U01 Com Fail
3U01 Com Fail
4U01 Com Fail
5U01 Com Fail
6U01 Com Fail
7U01 Com Fail
8U01 Com Fail
9U01 Com Fail
Error Codes are subject to change without any prior written notice.
Accelerometer fail to read ID information.
Lamp over voltage. (See BALLAST ERROR NOTE page 36)
Input voltage too high. (See BALLAST ERROR NOTE page 36)
Temperature too high. (See BALLAST ERROR NOTE page 36)
Asymmetry detected. (See BALLAST ERROR NOTE page 36)
Lamp under voltage. (See BALLAST ERROR NOTE page 36)
Input voltage too low. (See BALLAST ERROR NOTE page 36)
NTC defective. (See BALLAST ERROR NOTE page 36)
These fault modes are related to driver internal software and
Record and feedback that fixture once appeared lamp off issue
DESCRIPTION
Accelerometer calibration failure.
hardware malfunction.
because of ballast temp too high.
Humidity >85%
Humidity=70%
IC Chip failure.
IC Chip failure.
IC Chip failure.
IC Chip failure.
IC Chip failure.
IC Chip failure.
IC Chip failure.
IC Chip failure.
52