Ip65 Rated - Elation PROTEUS HYBRID WMG User Manual

Hide thumbs Also See for PROTEUS HYBRID WMG:
Table of Contents

Advertisement

IP65 RATED

The International Protection (IP) rating system is commonly expressed as "IP" (Ingress Protection) followed by two
numbers (i.e. IP65), where the numbers define the degree of protection. The first digit (Foreign Bodies Protection)
indicates the extent of protection against particles entering the fixture, and the second digit (Water Protection)
indicates the extent of protection against water entering the fixture. An IP65 rated lighting fixture is designed and
tested to protect against the ingress of dust (6), and low-pressure water jets from any direction (5).
NOTE: THIS FIXTURE IS INTENDED FOR TEMPORARY OUTDOOR USE ONLY!
Maritime/Costal Environment Installations: A coastal environment is seaside adjacent, and caustic to electronics
through exposure to atomized salt-water and humidity, whereas maritime is anywhere within 5-miles of a coastal
environment. A waterproof dome or similar device is recommended for use in permanent outdoor installations.
NOT suitable for maritime/coastal environment installations. Installing this fixture in a
maritime/coastal environment may cause corrosion and/or excessive wear to the interior and/or
exterior components of the fixture. Damages and/or performance issues resulting from
installation in a maritime/coastal environment will void the manufacturer's warranty, and will
NOT be subject to any warranty claims and/or repairs.
Maritime installations require additional preparation, and additional service intervals may be needed given the
maritime use. In general, IP ratings presuppose freshwater conditions VS maritime conditions, which are typically
more "caustic" to IP fixtures (both internally and externally). A duty-cycle may also be needed when units are
not in use. During times of high humidity and colder temperatures, condensation may occur internally so the
fixture may require a duty-cycle to bring it up to running temperature, allowing any accumulation of moisture to
be expelled via the vent valve. Recommendations can change based on installation environmental circumstances.
A waterproof dome or similar device is recommended for use in permanent outdoor installations. When using a
dome, refer to manufacturer recommendations for duty-cycle.
Exterior Maintenance: Inspect the exterior every 30-days. The chassis should be inspected for any signs of
contaminants. Inspect optics to determine if the lens is obstructed, then clean optics and chassis accordingly.
Based on initial finding, schedule maintenance accordingly, keeping in mind that exterior maintenance will be
required. Even if the luminaires are NOT in use, maintenance will still be needed given its location (exterior use).
The use of a durable type of wax on the chassis is recommended since it will help prevent contaminant build up.
Inspect both power and data lines for any signs of contaminants or corrosion. Periodically reapplying di-electric
grease, especially in coastal environments. If any signs of corrosion/contaminants are present, clean thoroughly,
and/or replace connectors, then reapply di-electric grease. Typically, this should be done annually, or any time
an opportunity presents itself. As a preventive measure, annual replacement of both vent valves is recommended.
The vent valve membrane can become contaminated and/or clogged causing improper venting of humidity within
the luminaire. Inspect all mounting hardware as a precaution.
Interior Maintenance: An internal inspection of the head is recommended within the first 1,000-1,500 hours of
use. The unit must be powered off/disconnected.
Inspect zoom/focus mechanism, clean optics, lubricate linear bearings (Krytox oil) as needed, inspect belts
for wear
Inspect all rotating effect wheels, manually rotate them, note any resistance
Inspect all remaining rotating belts for any wear
Inspect all fans, clean as needed, check rotation, check connections
Inspect CMY module, manually move flags and check for signs of resistance, and if needed, clean guide
rods first, then reapply a thin layer of grease (moly lube)
Clean interior with low-volume compressed air, then clean optics prior to reassembly of head covers
Although the base has limited moving parts, the pan belt should also be inspected for wear. Remember to always
perform an IP test anytime a cover is removed.
There is no specific time frame regarding the routine replacement of parts such as belts/stepper motors, PCBs,
or LEDs. These items should only be replaced on an as needed bases, except for cooling fans, which should be
replaced once the luminaries reach 10,000-hours. This is a prophylactic measure intended to keep the unit running
as cool as possible, insuring proper function of all internal components. A complete service breakdown is
available, please contact service@elationlighting.com for any needed parts or manuals.
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proteus hybridPrh021

Table of Contents